Cal. Civ. Code § 13VAC5-63-9999
Documents Incorporated by Reference
Operative Text
International Code Council, Inc., 200 Massachusetts Avenue, NW, Suite 250, Washington, DC 20001 ( http://www.iccsafe.org/ ): International Building Code - 2021 Edition International Energy Conservation Code - 2021 Edition International Existing Building Code - 2021 Edition International Fire Code - 2021 Edition International Fuel Gas Code - 2021 Edition International Mechanical Code - 2021 Edition International Property Maintenance Code - 2021 Edition International Plumbing Code - 2021 Edition International Residential Code - 2021 Edition International Swimming Pool and Spa Code - 2021 Edition International Zoning Code - 2021 Edition ICC 600 - 20, Standard for Residential Construction in High-wind Regions ICC/ANSI A117.1-17, Accessible and Usable Buildings and Facilities, Approved November 26, 2003 American Architectural Manufacturers Association, 1827 Walden Office Square, Suite 550 Schaumburg, IL 60173-4268 AAMA/WDMA/CSA 101/I.S.2/A440 - 05, North American Fenestration Standard/Specification for Windows, Doors, and Skylights American National Standards Institute, 25 West 43rd Street, Fourth Floor, New York, NY 10036 ANSI/DASMA 108 - 2017, Standard Method for Testing Sectional Garage Doors, Rolling Doors and Flexible Doors: Determination of Structural Performance Under Uniform Static Air Pressure Difference ANSI/RESNET/ICC 380 - 2019, Standard for Testing Airtightness of Building Enclosures, Airtightness of Heating and Cooling Air Distribution and Airflow of Mechanical Ventilation Systems ANSI LC 1/CSA 6.26-18, Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST) Air Conditioning Contractors of America, 2800 Shirlington Road, Suite 300, Arlington, VA 22206 ( https://www.acca.org/ ): Manual J-16, Residential Load Calculation, Eighth Edition Manual S-14, Residential Equipment Selection Air Movement and Control Association International, 30 West university Drive, Arlington Heights, IL 60004-1806 AMCA 500D-98, Laboratory Methods for Testing Dampers for Rating American Concrete Institute, 38800 Country Club Drive, Farmington Hills, MI 48331 ( http://www.concrete.org/ ) ACI 318-14, Building Code Requirements for Structural Concrete ACI 562-21, Assessment, Repair, and Rehabilitation of Existing Concrete Structures American Iron and Steel Institute, 25 Massachusetts Avenue, NW Suite 800, Washington, DC 20001 AISI S2 30-19 , Standard for Cold-formed Steel Framing - Prescriptive Method for One- and Two-family Dwellings American Petroleum Institute, 1220 L Street, NW, Washington, DC 20005-4070 ( http://www.api.org/ ): API 650-09, Welded Tanks for Oil Storage, Eleventh Edition, June 2007 (Addendum 1, November 2008, Addendum 2, November 2009, effective May 1, 2010) API 653-09, Tank Inspection, Repair, Alteration, and Reconstruction American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., 1791 Tullie Circle, NE, Atlanta, GA 30329-2305 ( https://www.ashrae.org/ ) ASHRAE 34-2019, Designation and Safety Classification of Refrigerants ASHRAE 62.1-13 , Ventilation for Acceptable Indoor Air Quality ASHRAE 90.1-04, Energy Standard for Buildings Except Low-rise Residential Buildings American Society of Testing Materials International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959 ( http://www.astm.org/ ): ASTM C90-2016A, Specification for Load-bearing Concrete Masonry Units ASTM C199-84 (2016), Standard Test Method for Pier Test for Refractory Mortar ASTM C315-07 (2016), Standard Specification for Clay Flue Liners and Chimney Pots ASTM C1261-13, Standard Specification for Firebox Brick for Residential Fireplaces ASTM D1003-13, Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics ASTM D15 57-12 e1, Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Modified Effort (56,000 ft-lbf/ft 3 (2700 kN-m/m 3 )) ASTM D2846/D2846--2017BE1, Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot- and Cold-Water Distribution Systems ASTM E84-2018B, Standard Test Methods for Surface Burning Characteristics of Building Materials ASTM E90-90, Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions ASTM E96-00e01, Standard Test Methods for Water Vapor Transmission of Materials ASTM E108-17, Standard Test Methods for Fire Tests of Roof Coverings ASTM E119-2018B, Standard Test Methods for Fire Tests of Building Construction and Materials ASTM E283-04, Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen ASTM E329-02, Standard Specification for Agencies Engaged in the Testing and/or Inspection of Materials Used in Construction ASTM E330/E330M-14, Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference ASTM F493-14, Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings ASTM E779-10, Standard Test Method for Determining Air Leakage Rate by Fan Pressurization ASTM E1354-17, Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter ASTM E18 27-11 , Standard Test Methods for Determining Airtightness of Buildings Using an Orifice Blower Door ASTM F1504-14, Standard Specification for Folded Poly (Vinyl Chloride (PVC) Pipe for Existing Sewer and Conduit Rehabilitation ASTM F1871-11, Standard Specification for Folded/Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation ASTM F2006-17, Standard Safety Specification for Window Fall Prevention Devices for Nonemergency Escape (Egress) and Rescue (Ingress) Windows ASTM F2090-17, Standard Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms National Standards of Canada, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W5N6 ( http://www.csa.ca ) CAN/CSA-B64.10-01, Manual for the Selection and Installation of Backflow Prevention Devices/Manual for the Maintenance and Field Testing of Backflow Prevention Devices, June 2003, CSA B805 - 2018/ICC 805 - 2018, Rainwater Harvesting Systems American Society of Mechanical Engineers, Three Park Avenue, New York, NY 10016-5990 ( https://www.asme.org/ ): ASME A17.1/CSA B 44-19 , Safety Code for Elevators and Escalators ASME A17.3 2008, Safety Code for Existing Elevators and Escalators ASME A18.1 2008, Safety Standard for Platform Lifts and Stairway Chairlifts American Society of Sanitary Engineering, 901 Canterbury Road, Suite A, Westlake, OH 44145 ( http://www.asse-plumbing.org/ ): ASSE 1010-2004, Performance Requirements for Water Hammer Arrestors ASSE 1022-03, Performance Requirements for Backflow Preventer for Beverage Dispensing Equipment ASSE 1024-04, Performance Requirements for Dual Check Valve Type Backflow Preventers (for Residential Supply Service or Individual Outlets) ASSE 5010-1013-1, Field Test Procedure for a Reduced Pressure Principle Assembly Using a Differential Pressure Gauge, 1991 ASSE 5010-1015-1, Field Test Procedure for a Double Check Valve Assembly Using a Duplex Gauge, 1991 ASSE 5010-1015-2, Field Test Procedure for a Double Check Valve Assembly Using a Differential Pressure Gauge - High- and Low-Pressure Hose Method, 1991 ASSE 5010-1015-3, Field Test Procedure for a Double Check Valve Assembly Using a Differential Pressure Gauge - High Pressure Hose Method, 1991 ASSE 5010-1015-4, Field Test Procedure for a Double Check Valve Assembly Using a Site Tube, 1991 ASSE 5010-1020-1, Field Test Procedures for a Pressure Vacuum Breaker Assembly, 1991 ASSE 5010-1047-1, Field Test Procedure for a Reduced Pressure Detector Assembly Using a Differential Pressure Gauge, 1991 ASSE 5010-1048-1, Field Test Procedure for a Double Check Detector Assembly Using a Duplex Gauge, 1991 ASSE 5010-1048-2, Field Test Procedure for a Double Check Detector Assembly Using a Differential Pressure Gauge - High- and Low-Pressure Hose Method, 1991 ASSE 5010-1048-3, Field Test Procedure for a Double Check Detector Assembly Using a Differential Pressure Gauge - High-Pressure Hose Method, 1991 ASSE 5010-1048-4, Field Test Procedure for a Double Check Detector Assembly Using a Site Tube, 1991 American Society of Civil Engineers/Structural Engineering Institute, 1801 Alexander Bell Drive, Reston, VA 20191-4400 ( http://www.asce.org/sei/ ) ASCE/SEI 7-22, Minimum Design Loads for Buildings and Other Structures ASCE/SEI 24-14, Flood Resistant Design and Construction ASCE/SEI 41-13, Seismic Evaluation and Retrofit of Existing Buildings American Wood Council, 222 Catocin Circle, Suite 201, Leesburg, VA 20175 ( http://www.awc.org/ ): AWC WFCM-18, Wood Frame Construction Manual for One- and Two-Family Dwellings National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471 ( http://www.nfpa.org/ ): NFPA 13-19, Installation of Sprinkler Systems NFPA 13R-19, Installation of Sprinkler Systems in Residential Occupancies Up to and Including Four Stories in Height NFPA 70-20, National Electrical Code NFPA 72-19, National Fire Alarm Code NFPA 91-20, Standard for Exhaust Systems for Air Conveying of Vapors, Mists and Particulate Solids NFPA 99-21, Health Care Facilities Code NFPA 101-21, Life Safety Code NFPA 105-19, Standard for the Installation of Smoke Door Assemblies NFPA 285-19, Standard Method of Test for the Evaluation of Flammability Characteristics of Exterior Nonload-bearing Wall Assemblies Containing Combustible Components NFPA 495-18, Explosive Materials Code NFPA 701-19, Standard Methods of Fire Tests for Flame-propagation of Textiles and Films NFPA 704, Standard System for the Identification of the Hazards of Materials for Emergency Response NFPA 7 20-15 , Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment National Fenestration Rating Council, Inc., 6305 Ivy Lane, Suite 140, Greenbelt, MD 20770 NFRC 100 - 2020, Procedure for Determining Fenestration Products U-factors NFRC 400 - 2001, Procedure for Determining Fenestration Product Air Leakage--Second Edition NSF 50-2015, Equipment for Swimming Pools, Spas, Hot Tubs and Other Recreational Water Facilities, NSF International, 789 Dixboro Road, P.O. Box 130140, Ann Arbor, MI 48113 ( http://nsf.org ) TFI RMIP-09, Aboveground Storage Tanks Containing Liquid Fertilizer, Recommended Mechanical Integrity Practices, December 2009, The Fertilizer Institute, 820 First Street, NE, Suite 430, Washington, DC 20002 Underwriters Laboratories, Inc., 333 Pfingsten Road, Northbrook, IL 60062 ( http://www.ul.com ): UL 217-15, Single- and Multiple-station Smoke Alarms-with revisions through November 2016 UL 109-97, Tube Fittings for Flammable and Combustible Fluids, Refrigeration Service and Marine Use UL 207—2009, Refrigerant-containing Components and Accessories, Nonelectrical—with revisions through June 2014 UL 263-11, Fire Tests of Building Construction and Materials UL 474-2015, Standard for Safety Dehumidifiers UL 484-2019, Standard for Room Air Conditioners UL 723-2018, Standard for Test of Surface Burning Characteristics of Building Materials UL 790-04, Standard Test Methods for Fire Tests of Roof Coverings-with Revisions through October 2008 UL 1784-15, Air Leakage Tests of Door Assemblies, with Revisions through February 2015 UL 2034-2017, Standard for Single and Multiple Station Carbon Monoxide Alarms, with revisions through September 2018 UL 2075-2013, Gas and Vapor Detectors and Sensors (Second Edition, March 5, 2013) UL/CSA 60335-2-40-2019, Standards for Household and Similar Electrical Appliances, Safety part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers UL/CSA 60335-2-89-2021, Household and Similar Electrical Appliances-Safety-Part 2-89: Particular Requirements for Commercial Refrigerating Appliances and Ice-Makers with an Incorporated or Remote Refrigerant Unit or Motor-Compressor UL 8782-2017, Pollution Control Units for Commercial Cooking Interim Remediation Guidance for Homes with Corrosion from Problem Drywall, April 2, 2010, Joint Report, Consumer Products Safety Commission and Department of Housing and Urban Development
Section 13VAC5-63-9999 of Virginia's Industrialized Building Safety Regulations establishes the specific editions of external technical codes and standards that are legally incorporated into Virginia's building regulatory framework. Rather than rewriting every technical requirement, the regulation adopts published documents from organizations such as the International Code Council, NFPA, ASTM, and others, making those documents enforceable as part of state law. The provision specifies exact editions and publication years, meaning only those particular versions carry regulatory authority, not newer or older editions unless separately adopted.
Plain English — not legal advice.
Property owners, developers, and contractors working on buildings subject to Virginia's Industrialized Building Safety Regulations must ensure that construction, renovation, and maintenance work conforms to the specific standard editions listed in 13VAC5-63-9999—not simply the latest available version of a given document. Compliant operators typically verify which edition of a referenced standard (such as the 2021 International Building Code or NFPA 70-20) applies before beginning design or construction work. Maintaining copies of or access to the incorporated standards is a common practice for demonstrating compliance during inspections.
General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.
For tenants, 13VAC5-63-9999 is relevant because the safety and habitability standards that govern the construction and maintenance of residential buildings in Virginia are defined in part by the technical documents incorporated here—including codes covering fire safety, plumbing, mechanical systems, and property maintenance. If a tenant believes a building condition may violate one of these incorporated standards, general enforcement paths include contacting the local building official or code enforcement office, or reaching out to a tenant-rights organization familiar with Virginia's building code framework. Understanding which standards apply can help tenants identify whether a reported condition falls under a specific incorporated code, such as the International Property Maintenance Code - 2021 Edition referenced in this provision.
General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.
Generated October 22, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.
Effective Timeline
References Out
No outbound references recorded yet for this provision.
References In
No inbound references recorded yet for this provision.