  § 59. Ventilation for shafts. 1. There shall be provided in the roof
directly over each stair, fire-stair, dumbwaiter, elevator or similar
shaft which extends to or within one story of a roof, a ventilating
metal skylight of the cross-sectional area of such shaft. Such skylight
need not, however, exceed twenty square feet in area. Where an existing
skylight is smaller than the dimensions or area prescribed in this
subdivision, no structural change shall be required, but a ventilating
metal skylight fitting the existing opening in the roof shall be
sufficient.  Every skylight shall be glazed with plain glass in the roof
of such skylight and shall be equipped with metal screens over and under
the skylight. In lieu of a skylight a window of the same area at the top
story shall be accepted.
  2. Whenever there is a flooring of solid construction at the top of
any enclosed stair, fire-stair, elevator or similar shaft, openings
shall be left near the top of such shaft for ventilation. Such openings
shall provide at least two hundred eighty-eight square inches of
unobstructed ventilation and shall communicate directly with the outer
air, or be otherwise ventilated in accordance with the provisions of the
local building code.
  3. It shall be unlawful to discharge into any such shaft any
inflammable or volatile gases, liquids or other thing or matter which
would endanger life.
Source: Legislative text reproduced verbatim
Plain English

New York Multiple Residence Law § 59 establishes ventilation requirements for vertical shafts—such as stairwells, elevator shafts, and dumbwaiter shafts—in multiple residences. Shafts that reach near the roof must have a metal skylight (or an equivalent top-story window) sized to match the shaft's cross-section, up to a maximum of twenty square feet, with plain glass glazing and metal screens above and below. Where a solid floor caps an enclosed shaft, openings providing at least 288 square inches of unobstructed airflow to the outside are required, and the law flatly prohibits discharging flammable or volatile gases or liquids into any such shaft.

Written by anthropic/claude-sonnet-4.6 · Reviewed on September 13, 2026

Plain English — not legal advice.

For Property Managers

Operators of multiple residences subject to N.Y. Mult. Resid. Law § 59 generally ensure that each qualifying shaft terminating near the roof is topped with a properly glazed, screened metal skylight—or an equivalent top-story window—sized to the shaft's cross-sectional area. Where an existing skylight is undersized, the law does not require structural reconstruction, but a ventilating metal skylight fitted to the existing roof opening is expected. Compliant operators also verify that any solid-floored shaft top has adequate ventilation openings meeting the 288-square-inch minimum, and they take care that no flammable or volatile substances are discharged into shaft spaces.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Residents living in buildings covered by N.Y. Mult. Resid. Law § 59 have an interest in knowing that shaft ventilation requirements exist to support both air quality and fire safety in stairwells and similar vertical spaces. If a skylight appears missing, unscreened, or improperly glazed, or if shaft ventilation openings seem blocked, these conditions may represent a violation of § 59 that can be reported to the local housing or building code enforcement agency. Tenants may also raise such conditions with a local tenant-rights organization or, where applicable, a rent board, to understand what documentation and complaint processes are available to them.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated September 13, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Current
Sep 22, 2014
Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

No inbound references recorded yet for this provision.

Related Rules

§ 105
Separation and ventilation of stairs
§ 107
Public halls
§ 173
Windows in rooms

Source Information

Snapshot SHA:
Fetched:Sep 13, 2026, 06:14 PM UTC