  § 107. Public halls.  1. Every public vestibule or other public hall
shall comply either with the provisions of section one hundred
forty-nine for non-fireproof multiple dwellings, so far as applicable,
or with the provisions of subdivision two of this section, except that
the provisions as to ventilation shall not apply to any part of an
entrance hall within sixty feet in a straight line from an entrance
door.
  2. If such a dwelling does not comply with the applicable provisions
of section one hundred forty-nine, it shall comply with all of the
following:
  a. Every public vestibule or hall shall be everywhere at least three
feet eight inches in clear width.
  b. Every such public vestibule or hall shall be separated from all
other parts of the dwelling by fireproof walls.
  c. All openings from such a public vestibule or hall to stairs,
fire-stairs, fire-tower balconies, shafts, apartments or suites of rooms
shall be protected by fireproof doors and assemblies, with the doors
self-closing, except that such doors and assemblies shall not be
required in any fireproof class B multiple dwelling for any apartment
consisting of one room opening directly upon a public hall or for any
apartment of three rooms or less in a college or school dormitory.
  d. Such a public vestibule or hall shall not be required to have a
window, but if it does not have a window opening to the outer air it
shall be equipped for artificial lighting and be properly lighted at all
times.
  e. Except for that part of an entrance hall within sixty feet in a
straight line from an entrance door such a public vestibule or hall
without a window to the outer air shall be ventilated to the outer air
by means of gravity vent flues at least twelve inches in each dimension
or by mechanical means approved by the department. There shall be at
least one vent flue opening of at least twelve inches in each dimension
for each one thousand cubic feet of air content of such public vestibule
or hall. Such vent flues shall be continuous for the height of the
dwelling and the openings at each story shall be equipped with fire
dampers held open by a fusible link at each opening and properly hooded
or provided with louvres at the top above the roof.
  f. If a window to the outer air is provided in any such public
vestibule or hall, such vestibule or hall shall nevertheless be
ventilated as provided in paragraph e, except that if such a window has
a glazed area of at least twelve square feet and at least one tenth of
the superficial floor area of the vestibule or hall, readily accessible
to the outer air to the extent of at least five and one-half square feet
of its area, no vent flues need be provided within a distance of forty
feet from each side of such window.
  3. The requirements of this section as to ventilation shall apply to
all parts of an entrance hall more than sixty feet distant in a straight
line from an entrance door, to all returns or recesses that lead to
elevators and extend farther from the hall which they adjoin than four
times their width, and to all other returns or recesses from entrance
halls that extend farther than their width.
  4. Any part of a public hall that is shut off from any other part of
such hall by a door or doors shall be deemed a separate hall.
Source: Legislative text reproduced verbatim
Plain English

N.Y. Mult. Dwell. Law § 107 establishes structural, fire-safety, and ventilation standards for public vestibules and hallways in non-fireproof multiple dwellings. Buildings must meet either the requirements of Section 149 or a specific set of alternative standards, which include minimum corridor widths of at least three feet eight inches, fireproof wall separation, self-closing fireproof doors at key openings, and defined ventilation arrangements. Ventilation requirements vary depending on a hall's distance from an entrance door, the presence of windows, and the geometry of any returns or recesses. Any portion of a public hall separated from the rest by a door is treated as its own distinct hall for purposes of these rules.

Written by anthropic/claude-sonnet-4.6 · Reviewed on September 13, 2026

Plain English — not legal advice.

For Property Managers

Operators of non-fireproof multiple dwellings should be familiar with N.Y. Mult. Dwell. Law § 107 and confirm that every public vestibule and corridor either satisfies Section 149 or meets all of the alternative criteria laid out in subdivision two. Compliant buildings generally maintain clear corridor widths of no less than three feet eight inches, fireproof wall construction separating halls from other dwelling areas, and self-closing fireproof door assemblies at stairways, shafts, and apartment openings. Ventilation systems—whether gravity vent flues sized to the air content of each hall segment or mechanically approved alternatives—are typically documented and inspected to ensure they meet the dimensional and operational requirements of § 107, including proper fire dampers with fusible links.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Under N.Y. Mult. Dwell. Law § 107, tenants in non-fireproof multiple dwellings have an interest in public hallways that meet minimum width, fire separation, door, lighting, and ventilation standards. If a hallway appears to lack self-closing fireproof doors, adequate lighting, or proper ventilation as described in § 107, tenants can document the conditions and file a complaint with the New York City Department of Buildings or the relevant local housing agency. Tenant-rights organizations can help residents understand whether observed conditions may constitute a violation and what general enforcement paths—such as housing court proceedings or agency complaints—may be available.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated September 13, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Current
Sep 22, 2014
Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

No inbound references recorded yet for this provision.

Related Rules

§ 105
Separation and ventilation of stairs
§ 173
Windows in rooms
§ 217
Lighting and ventilation of public halls and stairs

Source Information

Snapshot SHA:
Fetched:Sep 13, 2026, 06:01 PM UTC