Cal. Civ. Code § 110-11-1-.33
International Existing Building Code (IEBC), 2018 Edition with 2021 Georgia State Amendments
Operative Text
Georgia State Amendments to the International Existing Building Code (2018 Edition) Georgia Department of Community Affairs Community Development Division 60 Executive Park South, N.E. Atlanta, Georgia 30329-2231 (404) 679-3118 www.dca.ga.gov Revised January 1, 2021 GEORGIA STATE MINIMUM STANDARD EXISTING BUILDING CODE (INTERNATIONAL EXISTING BUILDING CODE WITH GEORGIA STATE AMENDMENTS) The INTERNATIONAL EXISTING BUILDING Code, 2018 Edition, published by the International Code Council, when used in conjunction with these and any other Georgia State Amendments to the INTERNATIONAL EXISTING BUILDING CODE, 2018 Edition, shall constitute the official Georgia State Minimum Standard Existing Building Code. GEORGIA STATE AMENDMENTS CODE REFERENCE: a) Replace all references to the ICC Electrical Code with references to the Georgia State Minimum Standard Electrical Code (National Electrical Code with Georgia State Amendments). b) Replace all references to the International Energy Conservation Code (IECC) with references to the Georgia State Minimum Standard Energy Code (IECC with Georgia State Supplements and Amendments). The Georgia State Minimum Standard Energy Code shall be used for heating and air conditioning equipment. c) Replace all references to "Accessibility" with a cross-reference to Title 30, Chapter 3 of the Official Code of Georgia Annotated (O.C.G.A.) and the Rules and Regulations of the Georgia Safety Fire Commissioner. d) The following table titled 'Codes Reference Guide' establishes specific primary and supplementary code applications and is to be applied by the authority having jurisdiction. CODES REFERENCE GUIDE Area Primary Supplement Occupancy Classification LSC IBC Building Construction Types including allowable height, allowable building areas, and the requirements for sprinkler protection related to minimum building construction types. IBC LSC Means of Egress LSC NONE Standpipes IBC IFC Interior Finish LSC NONE HVAC Systems IMC NONE Vertical Openings LSC NONE Sprinkler Systems minimum construction standard LSC NONE Fire Alarm Systems LSC NONE Smoke Alarms and Smoke Detection Systems State Statute and LSC NONE Portable Fire Extinguishers IFC NONE Cooking Equipment LSC and NFPA 96 NONE Fuel Fired Appliances IFGC NFPA 54 Liquid Petroleum Gas NFPA 58 NFPA 54 Compressed Natural Gas NFPA 52 NONE RESOURCES: Resource A is only a guideline and is not intended to be a document for specific adoption as it is not written in the format or language of ICC's International Codes and is not subject to the code development process. *Revise the International Existing Building Code, 2018 Edition, as follows: CHAPTER 3 PROVISIONS FOR ALL COMPLIANCE METHODS SECTION 301 ADMINISTRATION *Revise 301.3 Alteration, addition or change of occupancy to renumber exception add two exceptions as follows: 301.3 Alteration, addition or change of occupancy. Exception 1: (no change) Exception 2: Plumbing fixtures in existing multi-story buildings that are and will remain a B-Business occupancy shall be considered in compliance with the provisions of this code when it is technically infeasible to add fixtures required by present-day occupancy count calculations due to space or cost. Exception 3: Where existing buildings, core plumbing and other existing base building features cannot accommodate new tenant occupancy calculations, occupancy limit signage must be placed in common areas to indicate the occupancy limit of that specific area or the entry and exit points for the entire tenant area. (Effective January 1, 2021) CHAPTER 4 REPAIRS SECTION 408 PLUMBING *Revise 408.2 Water closet replacement to read as follows: 408.2 Water closet replacement The maximum water consumption flow rates and quantities for all replaced water closets shall be 1.28 gallons (4.84L) per flushing cycle. (Effective January 1, 2021) CHAPTER 7 ALTERATIONS-LEVEL 1 SECTION 702 BUILDING ELEMENTS AND MATERIALS *Revise [FG] 702.6.1 International Fuel Gas Code #2 to read as follows and delete 2.1 entirely: [FG] 702.6.1 International Fuel Gas Code. #2 Chapter 4, entitled "Gas Piping Installations". (Effective January 1, 2021) CHAPTER 12 HISTORIC BUILDINGS SECTION 1201 GENERAL *Revise Section 1201.1 'Scope' to add sentence at end of section to read as follows: 1201.1 Scope. . . . and change of occupancy. The Georgia Department of Natural Resources, Historic Preservation Office may be contacted for additional resources. (Effective January 1, 2021) End of Amendments.
Ga. Comp. R. & Regs. ch. 110-11-1 § 110-11-1-.33 establishes Georgia's official minimum standard for existing buildings by adopting the 2018 International Existing Building Code with state-specific amendments. Key modifications include substituting Georgia-specific electrical and energy codes, redirecting accessibility requirements to state law, and adding plumbing-related exceptions for multi-story business occupancies where adding fixtures is technically infeasible. Replaced water closets must meet a maximum flow rate of 1.28 gallons per flush, and buildings that cannot accommodate updated occupancy calculations must post occupancy limit signage in common areas.
Plain English — not legal advice.
Property owners and managers overseeing existing buildings in Georgia should be aware that Ga. Comp. R. & Regs. ch. 110-11-1 § 110-11-1-.33 governs renovation, repair, and alteration work by layering Georgia-specific requirements on top of the 2018 IEBC. Compliant operators generally ensure that any replaced water closets meet the 1.28-gallon-per-flush standard and that buildings unable to meet current occupancy-based plumbing calculations post the required occupancy limit signage in common areas. Work involving fuel gas, electrical systems, or energy conservation is evaluated under the corresponding Georgia minimum standard codes rather than the base ICC references.
General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.
Ga. Comp. R. & Regs. ch. 110-11-1 § 110-11-1-.33 sets the baseline construction and safety standards that apply when an existing building in Georgia undergoes repairs, alterations, or a change of occupancy, which can affect the condition and habitability of rental spaces. Tenants who believe building work in their unit or common areas does not meet these standards may raise concerns with the local authority having jurisdiction or consult a tenant-rights organization for guidance on available options.
General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.
Generated October 27, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.
Effective Timeline
References Out
No outbound references recorded yet for this provision.
References In
No inbound references recorded yet for this provision.