Cal. Civ. Code § 8-2-208
Compliance alternatives for excessive travel distances to approved exit.
Operative Text
Compliance alternatives for excessive travel distances to an approved exit include, but are not limited to, the following: (1) Install an approved smoke detection system throughout the building; (2) Install an approved complete automatic fire suppression system; (3) Subdivide the exit travel route with smoke-stop doors acceptable to the enforcement authority; (4) Increase the fire resistance rating of corridor walls and doors; or (5) Provide additional approved means of escape.
O.C.G.A. § 8-2-208 addresses situations in which a building's exit travel distance exceeds what is otherwise permitted under Georgia's building safety standards. Rather than mandating a single fix, the provision lists several recognized compliance alternatives—such as installing smoke detection or fire suppression systems, adding smoke-stop doors, upgrading corridor fire resistance ratings, or providing additional escape routes. The rule makes clear that this list is not exhaustive, meaning other solutions acceptable to the relevant enforcement authority may also qualify.
Plain English — not legal advice.
Property owners and managers overseeing buildings with exit travel distances that exceed code thresholds should be aware that O.C.G.A. § 8-2-208 provides a menu of recognized remediation options rather than a one-size-fits-all requirement. Compliant operators typically work with the local enforcement authority to select and implement one or more of the listed alternatives—such as a complete automatic fire suppression system or upgraded corridor fire resistance ratings—or to propose other solutions the authority finds acceptable. Documenting all communications with the enforcement authority and retaining records of any installed systems or construction upgrades is a practice commonly associated with maintaining compliance.
General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.
O.C.G.A. § 8-2-208 establishes that buildings with excessive exit travel distances must be brought into compliance through one or more recognized safety measures, which can include smoke detection systems, fire suppression systems, or additional means of escape. Tenants who believe their building may have unaddressed exit travel distance issues can contact the local building or fire code enforcement authority to inquire about inspections or open violations. Tenant-rights organizations and legal aid offices can also help residents understand how this provision may relate to habitability concerns or other protections available under Georgia law.
General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.
Generated October 28, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.
Effective Timeline
References Out
No outbound references recorded yet for this provision.
References In
Rules and statutes that cite this regulation
Related Rules
Source Information
Use this in your app
Access this data programmatically via our API