Ala. Admin. Code r. 535-X-13 § 535-X-13-.05

Soil Classification

In Force
Verified 10/16/2026 · Next check 10/23/2026
effective 10/16/2026AlabamaHabitability & Repair

Operative Text

Ala. Admin. Code r. 535-X-13 § 535-X-13-.05
The Commission hereby adopts the following soil classifications for the purpose of determining design loads, specifications and holding power of anchors and tiedown devices.

SOIL CLASS

TYPES OF SOILS

BLOW COUNT (ASTM)

TEST PROBE (1)

TORQUE VALUE (2)

I

Sound hard rock

Very dense and/or cemented........

NA

NA

II

Sands, coarse gravel and cobbles, preloaded silts, clays, and corals..........

40-up

More than

550 lbs.-in.

III

Medium-dense coarse, sands, sandy gravels, very stiff silts and clays.......

24-39

350-549

lbs.-in.

IV

Loose to medium dense sands, firm to stiff clays and silts, alluvian fill...

(3)

14-23

(3)

200-349

lbs.-in.

V

Peat, organic silt, inundate silts, loose fine sand, alluvium, loess, varied clays, fill, fly ash.............

0-14

0-200

lbs.-in.

(1) The test probe is a device for measuring the torque of soils to assist in evaluating the holding capability of the soils in which the anchor is placed. The test probe has a helix on it. The overall length of the helical section is 10.75 in.; the major diameter is 1.25 in.; the minor diameter is 0.81 in.; the pitch is 1.75 in. The shaft must be of suitable length for anchor depth.

(2) A measure synonymous with moment of a force when distributed around the shaft of the test probe.

(3) Below these values a registered professional engineer should be consulted.

(4) A C4 or C5 anchors that has been approved by the Commission must be used unless the soil is tested with a soil test probe or another Commission approved method.
Source: Legislative text reproduced verbatim
Plain English

Alabama Administrative Code r. 535-X-13 § 535-X-13-.05 establishes a five-tier soil classification system that the Alabama Real Estate Commission uses to determine how manufactured homes must be anchored and tied down. Each class—ranging from Class I (sound hard rock) to Class V (loose or organic soils)—is defined by measurable criteria including blow count, test probe torque values, and soil composition. The classification a site falls into directly governs the design loads and specifications required for anchors and tiedown devices used at that location.

Written by anthropic/claude-sonnet-4.6 · Reviewed on October 16, 2026

Plain English — not legal advice.

For Property Managers

Under Ala. Admin. Code r. 535-X-13 § 535-X-13-.05, operators installing manufactured homes generally ensure that the soil at each installation site is evaluated and assigned the correct class before anchor and tiedown systems are specified. For sites with blow counts or torque values falling below the Class IV thresholds noted in the provision, compliant operators typically engage a registered professional engineer to assess the soil conditions. When Class IV or V soils are present, operators also confirm that any anchors used are Commission-approved C4 or C5 models, or that an alternative Commission-approved testing method has been applied.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Ala. Admin. Code r. 535-X-13 § 535-X-13-.05 means that the ground beneath a manufactured home must be properly classified before the home's anchoring system is designed, which directly affects the structural safety of the home. If a tenant has concerns that a home was installed without proper soil evaluation or with anchors unsuited to the site's soil class, they may contact the Alabama Real Estate Commission to inquire about compliance. Tenant-rights organizations and legal aid services can also help residents understand what documentation they are entitled to request regarding the anchoring specifications used at their site.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated October 16, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Current
Oct 16, 2026
Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

No inbound references recorded yet for this provision.

Related Rules

§ 244.260
Compliance required
§ 14.567
ADOPTED BY REFERENCE
§ 244.340
Sewer and water connections

Source Information

Snapshot SHA:
Fetched:Oct 16, 2026, 12:36 PM UTC