Rensselaer, N.Y., Code of Ordinances ch. 121 § 121-49

Design and construction

In Force
Verified 11/7/2026 · Next check 2/5/2027
RensselaerStatutory Standards

Operative Text

Rensselaer, N.Y., Code of Ordinances ch. 121 § 121-49
Mobile homes shall be structurally sound, effectively insulated and capable of sustaining designed dynamic loading. A. Body and body framing. (1) Body frames shall be designed and constructed as complete units. Wall and floor surfaces shall be firmly attached to body framing members. Doors and windows shall be securely framed in place. Framing and exterior skin shall be surface treated or painted to prevent deterioration. (2) Roofs shall be pitched for proper drainage and shall be weathertight. Roof decks shall be of metal or noncombustible materials. (3) Wood body framing shall be of seasonal lumber and shall provide adequate support and rigidity. Members shall be joined so as to ensure permanent attachment to each other. (4) Metal body framing shall be of structural formed sections, riveted, bolted or welded together. Where different metals are joined, precaution shall be taken to prevent electrolytic action. (5) Insulation of floors, roof and exterior walls shall consist of noncombustible materials. (6) Ventilation shall be provided to minimize deterioration of structural members from condensation or other causes. B. Chassis. (1) The chassis shall extend substantially the length of the body and shall be capable of supporting the live and dead loads to which subjected. (2) The tongue or drawbar shall be secured to the chassis and shall be capable of supporting the weight of the forward end of the mobile home. If designed to support gas cylinders, the tongue shall be of sufficient strength and shall permit secure attachment. (3) The hitch shall be securely attached to the tongue so as to become an integral part of the tongue. (4) Axles, spring assemblies and wheels shall be capable of supporting the calculated loads. C. Placement. Placement of a mobile home on a mobile home stand by jacks or supports shall be such as to ensure the retention of the mobile home in a fixed position.
Source: Legislative text reproduced verbatim
Plain English

Section 121-49 of Rensselaer's Code of Ordinances establishes structural and construction standards that mobile homes must meet, covering the body framing, roofing, insulation, chassis, and placement. The rule requires that all components—from wall surfaces and doors to axles and hitches—be built and maintained to handle the loads and conditions they will encounter. Insulation and ventilation requirements are included to prevent deterioration, and placement on a mobile home stand must keep the unit in a fixed, stable position.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 7, 2026

Plain English — not legal advice.

For Property Managers

Under § 121-49, operators and owners of mobile homes in Rensselaer are generally expected to ensure that each unit meets the structural standards described, including properly pitched and weathertight roofs, noncombustible insulation materials, and a chassis capable of supporting all applicable loads. Compliant operators typically document the materials and construction methods used, ensure that metal joints are protected against electrolytic action where dissimilar metals meet, and confirm that placement on a mobile home stand results in a securely fixed position. Routine inspections of framing, exterior surfaces, and chassis components help demonstrate ongoing compliance with § 121-49.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Section 121-49 sets minimum structural and construction standards for mobile homes in Rensselaer, which means tenants living in such homes have a basis to expect that the unit's framing, roofing, insulation, chassis, and placement meet these requirements. If a mobile home appears to fall short of these standards—such as having inadequate insulation, a roof that does not drain properly, or an unstable placement—tenants may consider contacting the local code enforcement office to report potential violations of § 121-49. Tenant-rights organizations can help residents understand what documentation to gather and what local complaint processes may be available.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 7, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

Rules and statutes that cite this regulation

Rensselaer Code § 121-52
Rensselaer Code § 121-69
Rensselaer Code § 121-3
Rensselaer Code § 121-69
Rensselaer Code § 121-72
Rensselaer Code § 121-88
Rensselaer Code § 121-75
Rensselaer Code § 121-69
Rensselaer Code § 121-76
Rensselaer Code § 121-75
Rensselaer Code § 121-77
Rensselaer Code § 121-78
Rensselaer Code § 121-69
Rensselaer Code § 121-70
Rensselaer Code § 121-81
Rensselaer Code § 121-69
Rensselaer Code § 121-71
Rensselaer Code § 121-83
Rensselaer Code § 121-63
Rensselaer Code § 121-69
Rensselaer Code § 121-92
Rensselaer Code § 121-92
Rensselaer Code § 121-86
Rensselaer Code ch. 121

Related Rules

§ 244.850
Basement space may be habitable
§ 8
General application to all dwellings
§ 65
Artificial lighting

Source Information

Snapshot SHA:
Fetched:Nov 7, 2026, 10:34 AM UTC