A. General requirements. (1) Chimneys, flues, gas vents and their supports shall be installed and maintained so as to be structurally safe, durable, smoketight, noncombustible and capable of withstanding the action of flue gases without softening, cracking, corroding or spalling. (2) Such facilities shall effectively convey the products of combustion to the outer air. (3) Masonry chimneys, except approved prefabricated chimneys, shall have noncombustible foundations. (4) Flue linings shall be capable of withstanding the action of flue gas without softening, cracking, corroding or spalling at the temperature to which they will be subjected. (5) Opening for smoke pipes or gas-vent connections shall be provided with means for easy connection without restriction of flue. (6) No flue shall have smoke pipes or gas-vent connections in more than one story of a building. (7) Fuel-burning equipment and fireplaces located in different tenancies shall not be connected to the same flue. B. Firesafety. Chimneys, flues and gas vents shall be installed and maintained so that, under conditions of use, the temperature of any combustible material adjacent thereto, insulated therefrom or in contact therewith does not exceed a safe temperature. C. Spark arresters. A chimney or flue connected to an incinerator and a chimney or flue which may emit sparks shall be provided with a spark arrester of noncombustible construction. Spark arresters shall have sufficient total clear area to permit unrestricted passage of flue gases. Openings in spark arresters shall be of such size as to prevent passage of embers and to minimize clogging by soot.
Rensselaer, N.Y., Code of Ordinances ch. 121 § 121-27 establishes standards for chimneys, flues, and gas vents in residential and other buildings. These components must be structurally sound, smoketight, noncombustible, and capable of safely carrying combustion byproducts to the outside air without deteriorating. The rule also prohibits connecting fuel-burning equipment from different tenancies to the same flue, and requires spark arresters on chimneys connected to incinerators or those that may emit sparks.
Plain English — not legal advice.
Under ch. 121 § 121-27, compliant property operators generally ensure that all chimneys, flues, and gas vents are inspected and maintained in a structurally sound, smoketight, and noncombustible condition. Operators typically verify that no two separate tenancies share a common flue for fuel-burning equipment or fireplaces, and that any chimney connected to an incinerator or capable of emitting sparks is fitted with a properly sized noncombustible spark arrester. Routine documentation of inspections and any corrective maintenance helps demonstrate ongoing compliance with this provision.
General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.
Ch. 121 § 121-27 gives tenants a basis to raise concerns if chimneys, flues, or gas vents in their building appear deteriorated, improperly shared between units, or lacking required spark arresters. Tenants who observe cracking, corrosion, smoke infiltration, or other signs of non-compliance may report these conditions to the City of Rensselaer's code enforcement office. Tenant-rights organizations can help residents understand how to document conditions and what local complaint or inspection processes may be available.
General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.
Generated November 7, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.
Effective Timeline
References Out
No outbound references recorded yet for this provision.
References In
Rules and statutes that cite this regulation
Related Rules
Source Information
Use this in your app
Access this data programmatically via our API