Oswego, N.Y., Code of Ordinances ch. 149 § 149-34
Fuel oil
Operative Text
A. General requirements. Fuel oil shall be received, stored and conveyed by means of fixed liquidtight equipment. B. Storage tanks. (1) Tanks shall be provided with means for venting. (2) Tanks shall be installed and maintained so as not to be a hazard to the premises served or the surrounding property. C. Piping. (1) Automatically operated boilers and furnaces using fuel oil shall be provided with remote control to stop the flow of oil during fire or other emergency. (2) Filling, emptying and venting of tanks shall be by means of fixed piping. Pipes to underground tanks shall be pitched toward tanks. Terminals of fill and vent pipes shall be located outside buildings at a safe distance from building openings.
Oswego, N.Y., Code of Ordinances ch. 149 § 149-34 establishes standards for how fuel oil is handled on residential and commercial properties. Fuel oil must be received, stored, and moved through sealed, fixed equipment, and storage tanks must be properly vented and safely installed. Piping systems must be fixed and correctly configured, and any automatically operated boiler or furnace using fuel oil must have a remote shutoff control accessible during fires or other emergencies.
Plain English — not legal advice.
Property owners and managers subject to Oswego, N.Y., Code of Ordinances ch. 149 § 149-34 generally ensure that all fuel oil storage tanks are equipped with venting, are installed to avoid hazard to surrounding property, and are maintained in that condition over time. Compliant operators use fixed piping for all filling, emptying, and venting operations, pitch underground tank pipes toward the tank, and position fill and vent pipe terminals outside buildings at a safe distance from openings. Boilers and furnaces that operate automatically on fuel oil are equipped with a remote control capable of stopping oil flow in an emergency.
General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.
Under Oswego, N.Y., Code of Ordinances ch. 149 § 149-34, tenants have an interest in knowing that fuel oil systems in their building must meet specific safety standards, including proper tank venting, safe installation, and emergency shutoff controls on automated heating equipment. If a tenant observes conditions that appear to violate these requirements—such as improperly located piping terminals or missing emergency controls—they may consider reporting concerns to the City of Oswego's code enforcement office. Tenant-rights organizations can help residents understand what documentation to gather and what local complaint processes may be available.
General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.
Generated November 7, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.
Effective Timeline
References Out