Oneida, N.Y., Code of Ordinances ch. 77 § 77-74

Connection of equipment to chimneys or vents

In Force
Verified 11/7/2026 · Next check 2/5/2027
OneidaStatutory Standards

Operative Text

Oneida, N.Y., Code of Ordinances ch. 77 § 77-74
A. Equipment for burning solids or liquid fuel shall be connected to suitable chimneys or flues and shall not be connected to gas vents. Unvented heaters burning liquid fuel shall be prohibited. B. Fuel-burning space heaters located in sleeping rooms or rooms normally kept closed shall be connected to a suitable chimney, flue or gas vent. C. Gas-fired equipment shall be connected to a suitable chimney, flue or gas vent when the discharge of products of combustion into the space where the equipment is installed would be a hazard.
Source: Legislative text reproduced verbatim
Plain English

Oneida, N.Y., Code of Ordinances ch. 77 § 77-74 establishes rules about how fuel-burning equipment must be vented in residential and other occupied spaces. Equipment that burns solid or liquid fuel must connect to a proper chimney or flue and may not connect to a gas vent, and unvented liquid-fuel heaters are entirely prohibited. Space heaters in sleeping rooms or normally closed rooms must be vented to a chimney, flue, or gas vent, and gas-fired equipment must be vented whenever its combustion byproducts would pose a hazard in the space where it operates.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 7, 2026

Plain English — not legal advice.

For Property Managers

Property owners and managers operating under Oneida, N.Y., Code of Ordinances ch. 77 § 77-74 generally ensure that all fuel-burning appliances are connected to the correct type of venting system before tenants occupy a unit. Compliant operators remove or replace any unvented liquid-fuel heaters, verify that space heaters in bedrooms or closed rooms are properly connected to a chimney, flue, or gas vent, and assess gas-fired equipment to confirm combustion gases are safely discharged. Routine inspections and documentation of venting configurations are practices commonly associated with maintaining compliance with this provision.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Under Oneida, N.Y., Code of Ordinances ch. 77 § 77-74, tenants have an interest in knowing that fuel-burning appliances in their home are properly vented, since unvented liquid-fuel heaters are prohibited and improperly vented equipment can pose serious health and safety risks. If a tenant believes a heater or other fuel-burning appliance in their unit does not comply with this provision — for example, an unvented liquid-fuel heater in a bedroom — they may consider reporting the condition to the local code enforcement or housing authority in Oneida. Tenant-rights organizations and legal aid services can help tenants understand what options are generally available when a landlord has not addressed a venting concern covered by this provision.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 7, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

Rules and statutes that cite this regulation

Oneida Code § 77-12
Oneida Code § 77-88
Oneida Code § 77-17
Oneida Code § 77-20
Oneida Code § 77-32
Oneida Code § 77-34
Oneida Code § 77-25
Oneida Code § 77-26
Oneida Code § 77-32
Oneida Code § 77-34
Oneida Code § 77-4
Oneida Code § 77-32
Oneida Code § 77-32

Related Rules

§ 244.850
Basement space may be habitable
§ 8
General application to all dwellings
§ 65
Artificial lighting

Source Information

Snapshot SHA:
Fetched:Nov 7, 2026, 10:19 AM UTC