A. General. Plumbing systems shall be maintained in good, safe, sanitary, and serviceable condition. B. Water supply. (1) Potable water from an approved source shall be available at all times. The domestic water supply system of the building shall be connected to such approved source, shall not be subject to contamination, and shall not be connected to unsafe water supplies. (2) The source of water supply for a one- or two-family dwelling shall be a public water supply system when such system is within 100 feet of the premises on which the building is located, measured along a street, alley, or right-of-way, and a connection may lawfully be made thereto. (3) The source of water supply for a multiple dwelling shall be a public water supply system when such system is within 500 feet of the premises on which the building is located, measured along a street, alley, or right-of-way, and a connection may lawfully be made thereto. (4) Water supply systems shall be installed and maintained to provide at all times a supply of water to plumbing fixtures, devices, and appurtenances in sufficient volume and at pressures adequate to enable them to function satisfactorily. (5) Hot water shall be supplied in sufficient quantity at all times commensurate with the number of occupants and the normal usage. Water heaters or central water heating equipment shall be maintained in operating condition. (6) Hot-water supply systems shall be provided with safety devices designed to relieve hazardous pressures and excessive temperatures. C. Sewage and stormwater drainage systems shall be maintained so as to function properly and be kept free from obstructions, leaks and defects. (1) Sewage drainage. (a) Plumbing fixtures shall drain to a sewage system connected to a public sewer or approved system of sewage disposal. (b) The means of sewage disposal shall be a public sanitary sewer when it is available, and connection to such sewer shall be made in accordance with all provisions of applicable laws, rules and regulations. (c) No sewage from a plumbing system shall be discharged into the waters of the State of New York (as defined in state law), unless specifically approved by the authority having jurisdiction, under and in accordance with state law. (d) Adequate cleanouts shall be provided and maintained so that the pipes may be readily cleaned. (2) Storm drainage. (a) An approved system of stormwater disposal shall be provided for the safe and efficient drainage of roofs and paved areas, yards and courts and other open areas on the premises. (b) The means for stormwater disposal shall be in accordance with all applicable laws, ordinances, rules and regulations. (c) No stormwater shall be drained into sewers intended for sewage only or be discharged onto public sidewalks or streets. (3) Plumbing facilities. (a) Buildings and structures shall be provided with plumbing systems designed to dispose of the sewage from all fixtures and to furnish cold water to every water closet and urinal and hot and cold water to every sink, lavatory, bathtub, and shower required therein. (b) In one- and two-family dwellings, not wholly owner occupied, and in all multiple dwellings, hot water shall be furnished within a temperature range of 110° F. to 120° F. (c) There shall be provided within each dwelling unit plumbing fixtures consisting of at least: [1] One kitchen sink; [2] One water closet; [3] One bathtub or shower; and [4] One lavatory. (d) In multiple dwellings, each communal kitchen shall contain at least one kitchen sink, as provided in Table I. (e) In multiple dwellings where hotel units or lodging units are not provided with sanitary facilities therein, for each multiple of six male or six female occupants to be accommodated, or fractions thereof, there shall be provided, in separate rooms for each sex, plumbing fixtures consisting of at least: [1] One water closet; [2] One bathtub or shower; and [3] One lavatory. (f) In multiple dwellings where sleeping accommodations are arranged as dormitory units, for each multiple of 10 male or eight female occupants to be accommodated, or fractions thereof, there shall be provided, in separate rooms for each sex, plumbing fixtures consisting of at least: [1] One water closet; [2] One bathtub or shower; and [3] One lavatory. (g) Urinals may be substituted in a men's toilet room for not more than 1/3 of the required number of water closets. (h) Privies are prohibited on residential premises. D. Plumbing fixtures. (1) Plumbing fixtures shall be made of smooth, nonabsorbent material and free from concealed fouling surfaces. (2) Plumbing fixtures shall be spaced to be readily accessible for their intended use. (3) Plumbing fixtures shall be located in spaces that are accessible, lighted, and ventilated. E. Swimming pools. (1) Swimming pools shall be designed and maintained in accordance with generally accepted standards. (2) Drains shall be provided so that the pool can be safely and adequately drained. (3) Filtering, sterilizing, and auxiliary equipment shall be adequate to maintain the sanitary quality of water during each period the pool is in use. Equipment containing gases or disinfectants capable of giving off irritating, toxic, or flammable fumes shall be located in ventilated rooms. (4) The installation shall be designed and maintained to prevent dirt, sand, or other foreign matter from entering the bathing area. (5) An approved enclosure shall be provided around outdoor swimming pools or the property as provided in Chapter 464 , Swimming Pools, of this Municipal Code. F. Water supply tanks. (1) Water supply tanks shall be maintained watertight, verminproof, rodentproof and resistant to corrosion. (2) Supports for tanks shall be of noncombustible construction. (3) Tanks and their supports shall not be used to support equipment or structures other than for tank use, except where specially designed for such other use. (4) Means for emptying water supply tanks shall be maintained in proper working condition. (5) Potable water supply tanks for domestic supply and standpipe or automatic sprinkler systems shall be maintained to furnish water in sufficient quantity and pressure for such systems.
Source: Legislative text reproduced verbatim
Plain English

Section 300-29 of Mineola's Code of Ordinances establishes comprehensive standards for plumbing systems in residential buildings, covering everything from water supply and sewage drainage to fixtures, swimming pools, and water storage tanks. The rule requires that potable water be continuously available from an approved source, that hot water be supplied at adequate temperatures and quantities, and that all drainage systems remain free of obstructions and defects. Buildings must contain a minimum set of plumbing fixtures per dwelling unit, and stormwater must be managed through approved systems rather than discharged onto public streets or into sanitary sewers.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 9, 2026

Plain English — not legal advice.

For Property Managers

Operators of residential properties in Mineola are generally expected under § 300-29 to keep all plumbing systems—pipes, fixtures, water heaters, drainage lines, and storage tanks—in good, safe, sanitary, and serviceable condition at all times. Compliant operators typically ensure that one- and two-family dwellings connect to a public water supply when one is within 100 feet, and that multiple dwellings connect when a public system is within 500 feet, while also maintaining hot water delivery within the 110°F–120°F range required for non-owner-occupied and multiple dwellings. Routine maintenance practices generally include keeping sewage and stormwater drainage systems clear of obstructions, verifying that safety relief devices on water heaters are functional, and confirming that each dwelling unit contains the minimum required fixtures outlined in § 300-29(C)(3)(c).

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Under § 300-29, tenants in Mineola have a right to continuously available potable water, properly functioning drainage, and hot water supplied at adequate temperatures and quantities—conditions that landlords are obligated to maintain. If a plumbing system is deficient, such as lacking hot water, having clogged drains, or missing required fixtures like a kitchen sink or bathtub, that may constitute a violation of this provision. Tenants who believe these standards are not being met can document the conditions, notify their landlord in writing, and explore options such as filing a complaint with the appropriate local code enforcement authority or consulting a tenant-rights organization familiar with Mineola's housing code.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 9, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

Rules and statutes cited by this regulation

Mineola Code ch. 464
Not yet ingested

References In

Rules and statutes that cite this regulation

Mineola Code § 300-39
Mineola Code § 300-65
Mineola Code § 300-17
Mineola Code § 300-12
Mineola Code § 300-39

Related Rules

§ 244.290
Dwelling plumbing facilities required
§ 244.300
Shared bath dwelling unit plumbing facilities required
§ 244.310
Basement water closet

Source Information

Snapshot SHA:
Fetched:Nov 9, 2026, 06:57 PM UTC