Mineola, N.Y., Code of Ordinances ch. 300 (eCode360 ed. 2026) § 300-16

Railings and parapet walls

In Force
Verified 11/10/2026 · Next check 12/10/2026
MineolaStatutory Standards

Operative Text

Mineola, N.Y., Code of Ordinances ch. 300 (eCode360 ed. 2026) § 300-16
A. Railings or parapet walls shall be provided at open sides of balconies, mezzanines, porches, accessible roofs, exit passageways, areaways, motor vehicle parking decks and ramps and around floor openings. B. Railings or parapet walls shall be at least three feet six inches in height and designed to resist a lateral load at the top of at least 50 pounds per linear foot. Fixed openings in railings or parapet walls shall not exceed six inches in one dimension. C. Wheel bumper blocks shall be provided at perimeter and around floor openings of open motor vehicle parking decks and ramps. Wheel bumper blocks shall be continuous, at least eight inches in height, fastened to the floor, and designed to resist a minimum linear load of 300 pounds per foot.
Source: Legislative text reproduced verbatim
Plain English

Mineola, N.Y., Code of Ordinances ch. 300 § 300-16 establishes physical safety standards for railings and parapet walls at elevated or open areas of buildings, including balconies, porches, accessible roofs, and parking decks. These barriers must stand at least three feet six inches tall, be capable of withstanding a lateral load of at least 50 pounds per linear foot, and have no fixed openings wider than six inches in any single dimension. Parking decks and ramps also require continuous wheel bumper blocks of at least eight inches in height, fastened to the floor and rated to resist a minimum load of 300 pounds per foot.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 9, 2026

Plain English — not legal advice.

For Property Managers

Property owners and managers subject to Mineola, N.Y., Code of Ordinances ch. 300 § 300-16 generally ensure that all required railings and parapet walls are installed at balconies, mezzanines, porches, accessible roofs, exit passageways, areaways, and parking structures before those areas are made accessible. Compliant operators verify that barriers meet the minimum height of three feet six inches, are engineered to the specified load ratings, and contain no fixed openings exceeding six inches in one dimension. For properties with open motor vehicle parking decks or ramps, operators also confirm that continuous, properly fastened wheel bumper blocks meeting the load and height requirements are in place.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Tenants living in buildings with balconies, porches, accessible roofs, or parking structures in Mineola should be aware that § 300-16 of the Mineola Code of Ordinances sets minimum safety standards for railings, parapet walls, and wheel bumper blocks in those areas. If a railing appears to be missing, too low, structurally unsound, or has openings that seem wider than six inches, this may indicate a potential code violation worth documenting. Tenants can report suspected violations to the appropriate local building or code enforcement office, or consult a tenant-rights organization to understand available options.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 9, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

Rules and statutes that cite this regulation

Mineola Code § 300-39
Mineola Code § 300-65
Mineola Code § 300-17
Mineola Code § 300-12
Mineola Code § 300-39

Related Rules

§ 192-8
Penalties for offenses
§ 157-2
Legislative intent
§ 227-13
License fees

Source Information

Snapshot SHA:
Fetched:Nov 9, 2026, 06:56 PM UTC