Massena, N.Y., Code of Ordinances ch. 186 (eCode360 ed. 2026) § 186-34

Air conditioning and mechanical ventilation in multiple dwellings

In Force
Verified 11/10/2026 · Next check 12/10/2026
MassenaSpecific Conditions

Operative Text

Massena, N.Y., Code of Ordinances ch. 186 (eCode360 ed. 2026) § 186-34
A. Refrigerants that are highly flammable shall not be used in multiple dwellings. B. Direct systems using refrigerants that are flammable or toxic shall not be used for air-conditioning purposes. C. Ventilating systems. (1) Ventilating systems shall be installed and maintained so that the rapid spread of heat, flame or smoke through the system will be prevented, and so that under conditions of use the temperature of any combustible material adjacent thereto, or in contact therewith, will not exceed a safe temperature. (2) Stairways, passageways, exits, shafts, hoistways or attics shall not be used as plenum chambers. (3) Ducts shall be securely fastened in place and appropriately firestopped. (4) Ducts and other air-handling equipment shall be of noncombustible material. (5) Filters shall be installed and maintained so as not to constitute a fire or smoke hazard. (6) Ducts passing through or located within combustible construction shall be separated from such construction by a clearance of at least 1/2 inch or by a noncombustible insulating material at least 1/4 inch thick. (7) Air required for ventilation shall be taken from the exterior and shall be quality-controlled. (8) Exhaust air from a dwelling unit or a space whose contents emit odors, fumes or vapors shall not be circulated to other occupied spaces within the building. D. Air intake and exhaust openings. (1) Air intake and exhaust openings shall be installed, located and maintained, so as not to constitute a hazard of nuisance, and so as to prevent the possibility of fire, smoke, fumes or foreign matter being drawn into the system. (2) Ventilating systems shall be provided with adequate openings for incoming and outgoing air to obtain the required circulation. Intake openings shall provide air from an uncontaminated source. (3) Where openings for mechanical exhaust are located in spaces that also contain fuel-burning equipment, there shall be provided fixed intake openings from the exterior to supply sufficient air so that the fuel-burning equipment is not adversely affected. (4) Exhaust openings shall be located so that the exhaust air will not create a nuisance. E. Ventilation requirements. (1) Enclosures or spaces where heat, gases, vapors or odors may accumulate and become a potential source of hazard or nuisance shall be provided with adequate means of ventilation to remove such excess. (2) Public spaces shall be provided with means for obtaining air supply for the maximum number of persons for which such spaces are designed. F. Safety controls. (1) Manually operated controls shall be provided to stop the operation of all central fan equipment. Such controls shall be conspicuously identified and in readily accessible locations outside the fan room. (2) Every system using recirculated air and serving an assembly space or more than one fire area or more than one story of a building shall be provided with controls arranged so that under abnormal rise in temperature of the air in the system the fans causing normal circulation shall stop and require manual restart. (3) Every system for ventilating an assembly space shall be provided with an emergency switch conveniently located and with a durable sign giving instructions for shutting down the system in case of fire.
Source: Legislative text reproduced verbatim
Plain English

Section 186-34 of Massena's Code of Ordinances establishes safety standards for air conditioning and mechanical ventilation systems in multiple dwellings. The rule prohibits the use of highly flammable or toxic refrigerants, requires that ventilation components be made of noncombustible materials, and mandates that systems be designed and maintained to prevent the spread of fire, smoke, and hazardous fumes. It also requires that exhaust air from odor- or fume-producing spaces not be recirculated to other occupied areas, and that safety controls—including emergency shutoffs—be installed and accessible.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 9, 2026

Plain English — not legal advice.

For Property Managers

Operators of multiple dwellings subject to Massena Code ch. 186 § 186-34 generally ensure that refrigerants, duct materials, and filters meet the noncombustible and non-toxic standards specified in the provision. Compliant operators routinely inspect that ducts are securely fastened and firestopped, that air intakes draw from uncontaminated exterior sources, and that exhaust from units emitting odors or fumes is not recirculated to other occupied spaces. Manually operated fan shutoff controls and, where applicable, emergency switches for assembly spaces are kept conspicuously labeled and readily accessible outside the fan room.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Tenants in multiple dwellings covered by Massena Code ch. 186 § 186-34 have an interest in knowing that their building's ventilation and air conditioning systems must meet specific fire, smoke, and air-quality safety standards. If a tenant observes conditions that appear to violate these requirements—such as fumes from one unit circulating into another, or missing emergency shutoff controls—they may consider documenting the issue and reporting it to the appropriate local code enforcement or housing authority in Massena. Tenant-rights organizations can help residents understand what remedies or complaint processes may be available under local ordinance.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 9, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

Rules and statutes that cite this regulation

Massena Code § 186-61
Massena Code § 186-61
Massena Code § 186-5
Massena Code § 186-5

Related Rules

§ 244.290
Dwelling plumbing facilities required
§ 244.300
Shared bath dwelling unit plumbing facilities required
§ 244.310
Basement water closet

Source Information

Snapshot SHA:
Fetched:Nov 9, 2026, 10:23 PM UTC