Massena, N.Y., Code of Ordinances ch. 186 (eCode360 ed. 2026) § 186-26
A. General requirements. (1) Plumbing systems shall be maintained in sanitary and serviceable condition. (2) Plumbing systems shall be maintained so as not to weaken structural members nor cause damage or deterioration to any part of the building through fixture usage. B. Water supply. (1) Potable water from an approved source shall be available at all times in residential buildings. The domestic water supply system of the building shall be connected to such approved source, and shall not be subject to contamination. When available from a public source, the potable water supply system shall not be connected to private or unsafe water supplies. (2) Water supply systems shall be installed and maintained so as to provide at all times a supply of water to plumbing fixtures, devices and appurtenances in sufficient volume and at pressures adequate to enable them to function satisfactorily and without undue noise under all normal conditions of use. (3) Water supply systems shall be installed and maintained so that water used for purposes of cooling or heating shall not be reintroduced into the domestic water supply system nor be distributed through such equipment to plumbing fixtures. (4) Hot water supply systems shall be provided with safety devices arranged to relieve hazardous pressures and excessive temperatures. C. Sewage drainage system. (1) Plumbing fixtures shall be drained to a sewage drainage system and such system shall be connected to a public sewer or to an adequate and approved system of sewage disposal. (2) Where a public sewer is not available, a system shall be provided to receive and dispose of sewage without health hazard or nuisance. (3) Sewage or other waste which may be deleterious to surface or subsurface waters shall not be discharged into the ground or into a waterway unless it has first been rendered harmless through subjection to treatment in conformity with generally accepted standards. (4) Substances which will clog the pipes, produce explosive mixtures, destroy the pipes or their joints or interfere unduly with the sewage disposal process shall not be discharged into the building drainage system unless it is provided with approved devices suitable for intercepting such substances. (5) Each fixture directly connected to the sewage drainage system shall be equipped with a water seal trap. (6) Adequate cleanouts shall be provided and maintained so that the pipes may be readily cleaned. (7) The drainage system and its attendant vent piping shall be maintained so as to provide adequate circulation of air in all pipes in order that siphonage, aspiration or pressure will not cause a loss of trap seal under ordinary conditions of use. (8) Each vent terminal to the outer air shall be installed and maintained so as to minimize the possibilities of clogging, frost closure, the return of foul air to the building or the creation of a nuisance to adjacent premises. (9) Drains provided for fixtures, devices, appliances or apparatus containing food, water, sterile goods or similar materials shall be equipped with air brakes adequate to prevent contamination of such contents from any possible backup of sewage through the direct or indirect drainage piping. D. Storm drainage. (1) Roofs and paved areas, including yards and courts, shall be drained. Storm drainage shall be conveyed to an adequate and approved system of stormwater disposal where available. Storm drains shall be discharged in such manner that water will not flow onto sidewalks. (2) Where a drainage system may be subject to backwater, suitable provision shall be made to prevent its overflow into the building. (3) Leaders and gutters, if used, shall be constructed of noncombustible material. E. Plumbing facilities. (1) Buildings and portions thereof shall be provided with plumbing systems designed to dispose of the sewage from all fixtures and to furnish cold water to every water closet and urinal, and hot and cold water to every sink, lavatory, bathtub and shower required therein. In multiple dwellings, hot water shall be furnished at 130° F. to 140° F. temperature range from 6:00 a.m. to midnight. (2) There shall be provided within each dwelling unit plumbing fixtures consisting of at least: (a) One kitchen sink. (b) One water closet. (c) One bathtub or shower. (d) One lavatory. (3) Where multiple dwellings contain sleeping accommodations arranged as individual rooms or suites, for each multiple of six sleeping rooms, or fraction thereof, there shall be provided plumbing fixtures consisting of at least: (a) One water closet. (b) One bathtub or shower. (c) One lavatory. (4) Where multiple dwellings contain sleeping accommodations arranged as a dormitory, for each multiple of 15 persons, or fraction thereof, so accommodated there shall be provided and located adjacent thereto plumbing fixtures consisting of at least: (a) One water closet. (b) One bathtub or shower. (c) One lavatory. (5) Urinals may be substituted in men's toilet rooms for not more than 1/3 of the required number of water closets. (6) Privies, privy vaults and outhouses shall be prohibited on residential premises. F. Plumbing fixtures. (1) Plumbing fixtures shall be made of smooth nonabsorbent material and shall be free from concealed fouling surfaces. (2) Plumbing fixtures shall be so spaced as to be reasonably accessible for their intended use. (3) Plumbing fixtures shall be located in spaces that are accessible, lighted and ventilated. G. Swimming pools. (1) Water supply used for filling or for cleaning of the pool shall be clean. Water supply shall be protected against potential pollution from all sources, including cross-connection and backflow. (2) Drains shall be provided so that the pool can be safely and adequately drained. Drains shall be provided in floors surrounding the swimming pool and arranged so that water from such areas will drain without entering the pool. (3) Filtering, sterilizing and auxiliary equipment, where required, shall be adequate to maintain the sanitary quality of water during each period the pool is in use. Equipment containing gases or disinfectants capable of giving off irritating, toxic or flammable fumes shall be located in ventilated rooms. (4) The installation shall be arranged and maintained to prevent dirt, sand or other foreign matter from entering the bathing area. H. Water supply tanks. (1) Water supply tanks shall be installed and maintained so as to be watertight, verminproof, rodentproof, resistant to corrosion and capable of withstanding the working pressures under normal operation. (2) Supports for tanks shall be of noncombustible construction. (3) Tanks and their supports shall not be used to support equipment or structures other than for tank use, except where specially designed for such other use. (4) Means for emptying water supply tanks shall be provided and maintained in proper working condition. (5) Potable water supply tanks for domestic supply and standpipe or automatic sprinkler systems shall be installed and maintained to furnish water in sufficient quantity and pressure for such systems.
Source: Legislative text reproduced verbatim
Plain English

Section 186-26 of Massena's Code of Ordinances establishes comprehensive standards for plumbing systems in residential buildings, covering everything from water supply and sewage drainage to swimming pools and water storage tanks. The provision requires that potable water be continuously available from an approved, uncontaminated source, that sewage be properly routed to an approved disposal system, and that each dwelling unit contain at minimum a kitchen sink, water closet, bathtub or shower, and lavatory. Hot water in multiple dwellings must be supplied within a 130°F–140°F range between 6:00 a.m. and midnight, and all plumbing components must be kept in sanitary, structurally sound, and serviceable condition.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 9, 2026

Plain English — not legal advice.

For Property Managers

Under § 186-26 of Massena's Code of Ordinances, compliant property owners and managers routinely inspect plumbing systems to confirm they remain sanitary, free of leaks, and structurally sound. Operators of multiple dwellings verify that hot water is delivered within the 130°F–140°F range during the required hours and that each unit contains the minimum required fixtures—sink, water closet, bathtub or shower, and lavatory. Responsible managers also ensure that sewage drainage, storm drainage, vent piping, and any swimming pool or water tank equipment are maintained in accordance with the detailed standards set out in this section.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Section 186-26 of Massena's Code of Ordinances gives residential tenants the right to continuously available potable water, properly functioning sewage and drainage systems, and—in multiple dwellings—hot water at the required temperature range from 6:00 a.m. to midnight. Tenants who observe conditions such as contaminated water, missing or broken fixtures, or inadequate drainage may report those conditions to the appropriate local code enforcement or housing authority in Massena. Tenant-rights organizations can help residents understand what documentation to gather and what general options exist when a landlord fails to maintain plumbing in compliance with this provision.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 9, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

Rules and statutes that cite this regulation

Massena Code § 186-61
Massena Code § 186-61
Massena Code § 186-5
Massena Code § 186-5

Related Rules

§ 244.290
Dwelling plumbing facilities required
§ 244.300
Shared bath dwelling unit plumbing facilities required
§ 244.310
Basement water closet

Source Information

Snapshot SHA:
Fetched:Nov 9, 2026, 10:22 PM UTC