A. General requirements. (1) Residential buildings intended for occupancy between the first day of September and the first day of June of the following year shall be provided with heating equipment designed to maintain a temperature of not less than 70° F. at a distance of three feet and more from exterior walls and at a level of five feet above the floor in habitable spaces, kitchenettes, bathrooms and toilet rooms. The capability of the heating equipment to maintain such indoor temperature shall be based on the average of the recorded annual minimum outside temperatures for the locality. (2) In multiple dwellings, adequate heat shall be provided to maintain the indoor temperature in habitable spaces, kitchenettes, bathrooms and toilet rooms at 70° F. from 6:00 a.m. to 11:00 p.m. when the outside temperature falls below 55° F. B. Smoke control. Fuel-burning heat-producing equipment shall be installed and maintained so that the emission or discharge into the atmosphere of smoke, dust, particles, odors or other products of combustion will not create a nuisance or be detrimental to the health, comfort, safety or property of any person. C. Warm-air heating. Ducts and other air-handling equipment used for heating shall conform to the requirements of such equipment used for ventilating purposes. D. Locations for heat-producing equipment. Fuel-burning water heaters shall not be located in sleeping rooms, bathrooms or toilet rooms. E. Fuel supply connection. Fuel-burning equipment shall be permanently fastened and connected in place. Fuel supply connection to such equipment shall be made with pipe or tubing of solid metal. F. Installation and clearance. Where heat-producing equipment is installed on or adjacent to combustible materials, the location, insulation, clearance and the control of the equipment shall be such that the temperature on the surface of the combustible materials will not exceed a safe temperature. G. Air supply. Direct-fired heat-producing equipment and the enclosure in which it is located shall be provided with a supply of air adequate both for complete combustion at the rated gross output of the equipment and for the ventilation of the enclosure to prevent the accumulation of heat. Rooms containing fuel-burning equipment shall have such air supply provided by means of one or more openings to exterior or by means of fixed openings to interior spaces which open to the exterior. H. Removal of products of combustion. (1) Equipment for burning solid or liquid fuel shall be connected to suitable chimneys or flues and shall not be connected to gas vents. Unvented heaters burning liquid fuel shall be prohibited. (2) Fuel-burning space heaters located in sleeping rooms or rooms normally kept closed shall be connected to a suitable chimney, flue or gas vent. (3) Gas-fired equipment shall be connected to a suitable chimney, flue or gas vent when the discharge of products of combustion into the space where the equipment is installed would be a hazard. I. Safety devices. Equipment capable of developing hazardous pressures or temperatures shall be provided with means to relieve safely such pressures and temperatures. Controls for the safe operation of automatically operated heat-producing equipment shall be provided to function as follows: When failure or interruption of flame or ignition occurs, the fuel supply shall be cut off. When a predetermined temperature or pressure is exceeded, the input of additional heat shall be pressured or reduced to a safe rate. When the water level in a steam boiler drops below a predetermined level, the fuel supply shall be cut off. When failure or interruption of pilot light or main burner of liquefied petroleum gas equipment occurs, the fuel supply to each pilot light and main burner shall be cut off. J. Heating of garages. Fuel-burning equipment for garages servicing multiple dwellings shall be located in heater rooms, except that equipment burning gas or liquid fuel, located in the vehicle storage space, shall be permitted in stories at or above grade where elevated so as not to be exposed to possible accumulation of flammable gases.
Source: Legislative text reproduced verbatim
Plain English

Section 128-33 of LeRoy Village's Code of Ordinances establishes comprehensive standards for heating systems in residential buildings. From September 1 through June 1, heating equipment must be capable of maintaining at least 70°F in habitable spaces, kitchenettes, bathrooms, and toilet rooms, with multiple dwellings required to actively maintain that temperature between 6:00 a.m. and 11:00 p.m. whenever outside temperatures drop below 55°F. The provision also governs safe installation of fuel-burning equipment, including proper venting of combustion byproducts, clearances from combustible materials, adequate air supply, and required safety devices to prevent hazardous pressures or temperatures.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 9, 2026

Plain English — not legal advice.

For Property Managers

Operators of residential rental properties in LeRoy Village must ensure their heating systems comply with the full scope of § 128-33, including the capacity to reach 70°F in all covered rooms based on local minimum temperature averages. In multiple dwellings, landlords are generally expected to actively supply heat to maintain 70°F during the hours of 6:00 a.m. to 11:00 p.m. whenever outdoor temperatures fall below 55°F between September 1 and June 1. Compliant operators also keep fuel-burning equipment properly vented, permanently connected with solid metal fuel lines, safely cleared from combustible materials, and equipped with functioning safety controls as outlined throughout § 128-33.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Under § 128-33, tenants in LeRoy Village multiple dwellings have a right to adequate heat—at least 70°F in habitable spaces, kitchenettes, bathrooms, and toilet rooms—during specified hours whenever outside temperatures drop below 55°F in the heating season. If a landlord fails to provide heat meeting these standards, tenants may document the conditions (such as recording indoor and outdoor temperatures with timestamps) and report the issue to the local code enforcement or housing authority. Tenant-rights organizations familiar with New York housing law can help explain available remedies, which may include filing a formal complaint or raising a heating violation as a defense in relevant proceedings.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 9, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

Rules and statutes that cite this regulation

LeRoy Village Code § 128-57
LeRoy Village Code § 128-36
LeRoy Village Code § 128-70
LeRoy Village Code § 128-59
LeRoy Village Code § 128-4
LeRoy Village Code § 128-71
LeRoy Village Code § 128-62
LeRoy Village Code § 128-71
LeRoy Village Code § 128-70
LeRoy Village Code § 128-73
LeRoy Village Code § 128-59
LeRoy Village Code § 128-59
LeRoy Village Code § 128-70
LeRoy Village Code § 128-64
LeRoy Village Code § 128-63

Related Rules

§ 244.290
Dwelling plumbing facilities required
§ 244.300
Shared bath dwelling unit plumbing facilities required
§ 244.310
Basement water closet

Source Information

Snapshot SHA:
Fetched:Nov 9, 2026, 10:40 PM UTC