Garden City, N.Y., Code of Ordinances ch. 127 (eCode360 ed. 2026) § 127-32
Chimneys, flues and gas vents
Operative Text
A. General requirements. (1) Chimneys, flues, gas vents and their supports shall be installed and maintained so as to be structurally safe, durable, smoketight, noncombustible and capable of withstanding the action of flue gases without softening, cracking, corroding or spalling. (2) Such facilities shall effectively convey the products of combustion to the outer air. (3) Masonry chimneys, except approved prefabricated chimneys, shall have noncombustible foundations. (4) Flue linings shall be capable of withstanding the action of flue gas without softening, cracking, corroding or spalling at the temperature to which they will be subjected. (5) Opening for smoke pipes or gas vent connections shall be provided with means for easy connection without restriction of flue. (6) No flue shall have smoke pipe or gas vent connections in more than one story of a building. (7) Fuel-burning equipment and fireplaces located in different tenancies shall not be connected to the same flue. B. Firesafety. Chimneys, flues and gas vents shall be installed and maintained so that under conditions of use the temperature of any combustible material adjacent thereto, insulated therefrom or in contact therewith does not exceed a safe temperature. C. Spark arresters. A chimney or flue connected to an incinerator and a chimney or flue which may emit sparks shall be provided with a spark arrester of noncombustible construction. Spark arresters shall have sufficient total clear area to permit unrestricted passage of flue gases. Openings in spark arresters shall be of such size as to prevent passage of embers and to minimize clogging by soot.
Garden City, N.Y., Code of Ordinances ch. 127 § 127-32 establishes structural and safety standards for chimneys, flues, and gas vents in residential and other buildings. These systems must be built and kept in a condition that safely carries combustion byproducts to the outside air, resists heat damage, and does not allow dangerous temperatures to reach nearby combustible materials. Where a chimney or flue connects to an incinerator or could emit sparks, a properly designed spark arrester must be installed to prevent embers from escaping while still allowing gases to flow freely.
Plain English — not legal advice.
Under Garden City, N.Y., Code of Ordinances ch. 127 § 127-32, compliant property operators generally ensure that all chimneys, flues, and gas vents are inspected and maintained on a regular basis to confirm they remain structurally sound, smoketight, and free of cracks, corrosion, or spalling. Operators also verify that fuel-burning equipment serving separate tenancies is never connected to a shared flue, and that masonry chimneys rest on noncombustible foundations. Where incinerators or spark-emitting appliances are present, maintaining a properly sized, noncombustible spark arrester in good working order is part of routine compliance under this section.
General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.
Section 127-32 of the Garden City Code gives tenants a basis to raise concerns if chimneys, flues, or gas vents in their building appear damaged, improperly vented, or otherwise unsafe. Conditions such as visible cracking, signs of smoke leakage, or shared flues between separate units may constitute violations of this provision. Tenants who observe such conditions can document them and report them to the appropriate Garden City building or housing code enforcement office, or consult a tenant-rights organization to understand available options.
General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.
Generated November 10, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.
Effective Timeline
References Out
No outbound references recorded yet for this provision.
References In
No inbound references recorded yet for this provision.