Elmira, N.Y., Code ch. 8, art. V § 8-429
Fire protection in multiple dwellings
Operative Text
13-101.1. General. (a) Fire protection equipment, including fire alarm, fire detecting, watchman, sprinkler and standpipe systems and portable fire extinguishers, shall be maintained in proper operating condition at all times. (b) Sprinkler and standpipe systems shall have an adequate water supply available at all times. (c) Fire department connections shall be conspicuously identified and maintained readily accessible for fire department use. 13-101.2. Fire alarm and fire detecting systems. Fire alarm and fire detecting systems shall be suitable for their respective purposes. Equipment and devices comprising such systems shall be of the approved type, and shall conform to generally accepted standards. 13-101.3. Sprinkler systems. (a) Sprinkler systems shall be maintained in good condition, free from mechanical injury. Sprinkler heads shall be maintained clean, free of corrosion and paint, and not bent or damaged. (b) Valves controlling water supply to sprinklers shall be secured in the open position. (c) Supports for piping and equipment shall be structurally sound. (d) Portions of the system subject to freezing shall be appropriately protected. (e) Storage of materials shall not interfere with the effective discharge of water from the sprinkler heads. (f) Water supply for the sprinklers shall be adequate to extinguish the fire effectively or confine it without spread. 13-101.4. Standpipe systems. (a) Gate valves at hose stations shall be maintained tight against leaks. (b) Hose shall be in proper position ready for operation, dry and free of deterioration. (c) Hose stations shall be conspicuously identified, located for easy accessibility, and installed to provide for the quick and easy use of equipment. Cabinets shall have keyless doors. (d) Valves in the water supply pipe for the standpipe system shall be open at all times. 13-101.5. Portable fire extinguishers. (a) Portable fire extinguishers shall be of the following types: approved multipurpose dry chemical type, classified for use on class A (combustible), class B (flammable liquids) and class C (electrical) fires; approved water-type, classified for use on class A fires. Extinguishers shall have at least a two-unit rating, in accordance with generally accepted standards. (b) Portable fire extinguishers shall be maintained in an efficient and safe operating condition. (c) Portable fire extinguishers shall be in their designated location and clearly visible, except that they may be located in an enclosure or recess conspicuously identified as containing a fire extinguisher.
Elmira Code ch. 8, art. V § 8-429 establishes comprehensive maintenance standards for fire protection systems in multiple dwellings, covering fire alarms, detection equipment, sprinkler systems, standpipe systems, and portable fire extinguishers. All such equipment must remain in proper working order at all times, with adequate water supplies, accessible connections, and unobstructed operation. Specific requirements address everything from corrosion-free sprinkler heads and leak-tight hose valves to the placement and visibility of portable extinguishers.
Plain English — not legal advice.
Operators of multiple dwellings subject to Elmira Code ch. 8, art. V § 8-429 generally conduct routine inspections of all fire protection equipment to confirm that sprinkler heads are clean and undamaged, standpipe hose stations are accessible with keyless cabinet doors, and portable extinguishers are in their designated, clearly visible locations. Compliant operators keep water supply valves open and secured, protect freeze-vulnerable system components, and ensure stored materials never obstruct sprinkler discharge. Fire department connections are kept conspicuously marked and unobstructed at all times.
General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.
Tenants living in multiple dwellings covered by Elmira Code ch. 8, art. V § 8-429 have an interest in knowing that their building's fire protection systems—sprinklers, alarms, standpipes, and extinguishers—must be kept in proper operating condition by the property owner. If fire protection equipment appears damaged, obstructed, missing, or otherwise out of service, residents may report concerns to the City of Elmira's code enforcement or housing inspection office. Tenant-rights organizations can also help residents understand what documentation to gather and what local complaint processes are available.
General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.
Generated November 6, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.
Effective Timeline
References Out
No outbound references recorded yet for this provision.
References In
Rules and statutes that cite this regulation
Related Rules
Source Information
Use this in your app
Access this data programmatically via our API