Elmira, N.Y., Code ch. 8, art. V § 8-419
13-91.1. General.
(a) Fuel gas piping systems shall be installed and maintained gastight, safe and operative under conditions of use.
(b) Fuel gas piping systems shall provide a supply of gas sufficient to meet the maximum expected demand of gas-burning equipment and appliances connected thereto.
13-91.2. Shutoff valves.
(a) On one- and two-family dwellings, gas piping systems shall have at least one accessible valve for shutting off all gas supply, except that systems supplied with gas at pressures exceeding one psi gauge shall have at least two accessible valves for shutting off all gas supply. Where two valves are required, one valve shall be located outside at a safe distance from the building, and shall be suitably protected against unauthorized use, and the other shall be located ahead of the meter and as close as practicable to the point of service entrance.
(b) In multiple dwellings, gas piping systems supplied from utility mains shall have at least two accessible valves for shutting off all gas supply. One valve shall be located outside and at a safe distance from the building, and shall be suitably protected against unauthorized use, and the other shall be located ahead of the meter and as close as practicable to the point of service entrance.
(c) An easily accessible shutoff valve, or cock, shall be provided in the piping in close proximity to, and ahead of every gas appliance, or outlet for a gas connection, or at some other location approved by the agency.
13-91.3. Service equipment for gas supplied from utility mains.
(a) Gas meters shall be located in spaces that are dry, ventilated and accessible. Gas meters shall be located near the point of entry of the gas service, and remote from open flame, heat-producing equipment, or other heat sources.
(b) Gas services, gas meters and gas pressure regulators shall be located so that they are protected from damage and tampering by unauthorized personnel.
13-91.4. High pressure gas. Any service connection supplying gas at a pressure in excess of one psi gauge shall be provided with a device to reduce such pressure to not more than one-half psi gauge prior to entering the meter.
13-91.5. Liquefied petroleum gas.
(a) Liquefied petroleum gas in liquid form shall not be stored in buildings.
(b) Liquefied petroleum gas shall not be vaporized by devices utilizing open flame or open electrical coil.
(c) Where two or more containers are installed, connection shall be arranged so that containers can be replaced without shutting off the flow of gas equipment.
(d) Containers shall be protected against physical damage, and located so as not to be a hazard to the premises served. Nonportable containers shall rest on stable noncombustible supports.
(e) Liquefied petroleum gas shall be odorized, so that the presence of gas will be recognizable by a distinctive odor.
(f) Systems shall be provided with safety devices to relieve excessive pressures to the outer air, at a safe distance from building openings.
(g) Systems supplied from containers not exceeding 125 gallons of capacity shall have at least one accessible valve for shutting off the gas. Such valve shall be located outside the building.
(h) Systems supplied from containers exceeding 125 gallons of capacity shall have at least two accessible valves for shutting off the main gas supply. Shutoff valves shall be located in conformity with the requirements of subsections 13-91.2(a) and (b) of this section.
Source: Legislative text reproduced verbatim
Plain English

Elmira Code ch. 8, art. V § 8-419 establishes comprehensive safety standards for fuel gas piping systems in residential buildings. Gas piping must be gastight, properly maintained, and capable of meeting peak demand from all connected appliances. The provision also sets specific requirements for shutoff valve placement, meter location, high-pressure gas regulation, and the handling and storage of liquefied petroleum gas (LPG), including mandatory odorization so leaks can be detected by smell.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 6, 2026

Plain English — not legal advice.

For Property Managers

Under Elmira Code ch. 8, art. V § 8-419, compliant property operators ensure that all fuel gas piping is installed and maintained in a gastight and operative condition, with the correct number and placement of accessible shutoff valves depending on building type and gas pressure. For one- and two-family dwellings, at least one shutoff valve is required, while multiple dwellings and higher-pressure systems require two, with one located outside at a safe distance. Operators also keep gas meters in dry, ventilated, accessible locations away from heat sources, and ensure any LPG containers are properly supported, odorized, and equipped with pressure-relief safety devices.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Elmira Code ch. 8, art. V § 8-419 gives tenants a basis to expect that fuel gas systems in their homes are safely installed, properly maintained, and equipped with accessible shutoff valves and correctly placed meters. If a tenant notices signs of a gas leak, improperly located equipment, or a missing shutoff valve, these conditions may constitute a violation of this provision. Tenants can report such concerns to the City of Elmira's code enforcement office, raise the issue as a defense in relevant housing proceedings, or seek guidance from a local tenant-rights organization.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 6, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

Rules and statutes that cite this regulation

Elmira Code § 8-359
Elmira Code § 8-428
Elmira Code § 8-428
Elmira Code § 8-428
Elmira Code § 8-403
Elmira Code § 8-426
Elmira Code § 8-428
Elmira Code § 8-428
Elmira Code § 8-359

Related Rules

§ 244.260
Compliance required
§ 14.567
ADOPTED BY REFERENCE
§ 244.340
Sewer and water connections

Source Information