Bellport, N.Y., Code of Ordinances ch. 9 (eCode360 ed. 2026) § 9-80
Fire and smoke detection systems
Operative Text
Every multiple-unit dwelling and every multiple-residence facility shall be equipped with a supervisory circuited fire and smoke detection system. Smoke detection sensors shall be located in or adjacent to all sleeping quarters, and thermal detection units shall be located in all other areas, including attics, basements, utility rooms and storage rooms. Each area between fire walls shall be separately zones. The annunciator panel and alarm bells shall be located where specified by the chief fire marshal.
Bellport, N.Y., Code of Ordinances ch. 9 § 9-80 requires that every multi-unit dwelling and multi-residence facility be outfitted with a supervisory circuited fire and smoke detection system. Smoke sensors must be placed in or near all sleeping areas, while thermal detection units are required in all other spaces, including attics, basements, utility rooms, and storage rooms. Each section separated by fire walls must be independently zoned, and the annunciator panel and alarm bells must be positioned according to the chief fire marshal's specifications.
Plain English — not legal advice.
Operators of multiple-unit dwellings subject to Bellport, N.Y., Code of Ordinances ch. 9 § 9-80 generally ensure that a supervisory circuited detection system is installed and maintained throughout the property, with smoke sensors covering sleeping areas and thermal units covering all remaining spaces. Compliant operators also verify that each fire-wall-separated zone is independently wired and that the annunciator panel and alarm bells are placed in locations approved by the chief fire marshal. Keeping documentation of system inspections and any communications with the fire marshal's office is a common practice among property managers seeking to demonstrate ongoing compliance.
General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.
Under Bellport, N.Y., Code of Ordinances ch. 9 § 9-80, residents of multiple-unit dwellings have an interest in confirming that their building is equipped with the required supervisory circuited fire and smoke detection system, including properly placed smoke sensors near sleeping areas and thermal units throughout other spaces. If a tenant believes the system is absent or inadequate, general enforcement paths include reporting the concern to the local fire marshal's office or the appropriate municipal code enforcement authority. Tenant-rights organizations can also help residents understand what documentation to gather and what options may be available.
General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.
Generated November 10, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.
Effective Timeline
References Out
No outbound references recorded yet for this provision.
References In
No inbound references recorded yet for this provision.