The ICC International Property Maintenance Code, Edition 2021, as adopted in section 8-328 , is hereby amended as follows: (1)
Section 101.1 is amended as follows:
101.1 Title. These regulations shall be known as the International Property Maintenance Code of the Village, hereinafter referred to as "this code".
(2) Section 109.1 is deleted and replaced as follows:
112.1 Imminent danger. When, in the opinion of the code official, there is imminent danger of failure or collapse of a building or structure which endangers life, or when any structure or part of a structure has fallen and life is endangered by the occupation of the structure, or when there is actual or potential danger to the building occupants or those in the proximity of any structure because of explosives, explosive fumes or vapors or the presence of toxic fumes, gases or materials, or operation of defective or dangerous equipment or when the structure is unfit for human habitation, the code official is hereby authorized and empowered to order and require the occupants to vacate the premises forthwith. The code official shall cause to be posted at the primary entrance to such structure a notice of condemnation. It shall be unlawful for any person to enter such structure except for the purpose of securing the structure, making the required repairs, removing the hazardous condition or of demolishing the same.
(3) Section 202 is amended as follows:
Add the Following Definition: DEBRIS. Materials which are placed outside in a haphazard manner, which may create rodent and pest harborage, or items which are not intended or customarily stored outdoors and which if left exposed and unprotected from the elements have, or potentially will, deteriorate by reason of vandalism, moisture and exposure. Such materials can include rubbish and items which might otherwise be considered useable such as furniture, appliances, boards intended for interior use, cardboard boxes of items, clothing, dishes, machinery, and so forth.
(4) Section 302.1 is amended as follows:
302.1 Sanitation. All exterior property areas and premises shall be maintained in a clean, safe and sanitary condition free from any accumulation of garbage, debris and rubbish. The occupant shall keep that part of the exterior property that such occupant occupies or controls in a clean and sanitary condition. The Code Official may order the removal of garbage, debris and rubbish pursuant to Illinois Compiled Statutes 65 ILCS 5/11-20-13.
(5) Section 302.4 is deleted and replaced as follows:
302.4 Weeds. All premises and exterior property shall be maintained free from weeds or plant growth in excess of 7 inches (179 mm). All noxious weeds shall be prohibited. Weeds shall be defined as overgrowth, underbrush, all grasses, annual plants and vegetation. However, this term shall not include trees or shrubs or cultivated flowers and sand gardens. All weeds shall be removed pursuant to Illinois Compiled Statutes 65 ILCS 5/11-20-7 and Chapter 22, Article three of the Village of Machesney Park Code.
(6) Section 302.7 is amended as follows:
302.7 Accessory Structures. Accessory structures, including attached garages, detached garages, fences, walls and retaining walls, shall be maintained structurally sound and in good repair. All garages where a garage door was intended or installed must be provided with an approved and functioning garage door.
(7) Section 302.8 is deleted in its entirety and replaced as follows:
302.8 Motor Vehicles. Except as provided for in other regulations, no currently unregistered or inoperable motor vehicle shall be parked, kept or stored on any premises, with the exception of not more than one unregistered or inoperable vehicle stored within a totally enclosed permanent structure. No vehicle shall at any time be in a state of major disassembly, disrepair, or in the process of being stripped or dismantled. Painting of vehicles is prohibited unless conducted in an approved spray booth. In accordance with the procedures outlined in section 5/11-40-3 of the Illinois Municipal Code (65 ILCS 5/11-40-3) and section 5/4-201 of the Illinois Vehicle Code (625 ILCS 5/4-201) the abandonment of vehicles is prohibited on public or private property and the village is authorized to remove such abandoned or inoperable vehicles Exception: Uses that are properly zoned for such storage.
(8) Section 302.10 is added as follows:
302.10 Cisterns. Pursuant to Illinois Compiled Statutes 65 ILCS 5/11-20-10, cisterns unused and abandoned shall be filled with clean fill earthen material and sealed with a non-removable cover as prescribed by the Code Official.
(9) Section 302.11 shall be added as follows:
(10) Section 304.3 is amended as follows:
304.3 Premises identification. Buildings shall have village assigned address numbers, building numbers, or approved building identification placed in a position that is plainly legible and visible from the street or road to which the building is addressed. These numbers shall contrast with their background. Address numbers shall be Arabic numerals or English alphabet letters. Numbers shall be a minimum of four inches high when less than 100 feet from the street, with a minimum stroke width of 0.5 inch (12.7 mm). When over 100 feet and less than 200 feet from the street, the numbers shall be five inches (128 mm) high and a minimum stroke width 0.75 inch (19 mm). When over 200 feet from the street, the numbers shall be seven inches (179 mm) high and a minimum stroke width 0.75 inch (19 mm). Wherever the primary entry doors are visible from the address street, the numbers shall be displayed above, on or adjacent to the primary entry doors. Numbers shall be displayed where they remain visible at all times. Where a building is more than 500 feet from the street, displaying additional numbers on a building identification sign or other approved location near and viewable from the street is encouraged.
(11) Section 304.14 is amended as follows:
304.14 Insect Screens. During the period from April 1 to November 1 every door, window and other outside opening used, or structure required, for ventilation purposes serving any building containing habitable rooms, food preparation areas, food service areas, or any areas where products to be included or used in food for human consumption are processed, manufactured, packaged or stored, shall be supplied with approved tightly fitting screens of not less than 16 mesh per inch (16 mesh per 25 mm) and every swinging door or screen door used for insect control shall have a self-closing device in good working condition. Exception: Screen doors shall not be required for out-swinging doors or other type of openings which make screening impractical, provided other approved means, such as air curtains or insect repellant fans are employed.
(12) Section 308.3.1 is amended as follows:
308.3.1 Garbage facilities. The owner or tenant of every dwelling shall supply one of the following; an approved mechanical food waste grinder in each dwelling unit; or an approved leak proof, covered, outside garbage container.
(13) Section 308.4 is added as follows:
308.4 Rubbish, Debris and Garbage on Parkways. No rubbish, debris or garbage shall be disposed of at any site other than those approved by the Village. Every property shall be required to be served, at the property owners' or tenants' expense, with refuse/garbage removal service through the village's approved refuse/garbage removal contractor.
(14) Section 404.3 Exceptions: 2. is amended as follows:
404.3 Minimum ceiling heights. Exceptions:
2. Basement rooms in one- and two- family dwellings occupied exclusively for bathrooms, toilet rooms, laundry areas, study areas or recreation purposes, having a ceiling height of not less than 6 feet 8 inches (2033 mm) with not less than 6 feet 4 inches (1932 mm) of clear height under beams, girders, ducts and similar obstructions.
(15) Section 501.1 is amended as follows:
501.1 Scope. The provisions of this chapter and the current Illinois State Plumbing Code listed in Chapter 8 shall govern the minimum plumbing systems, facilities and plumbing fixtures to be provided.
(16) Section 601.1 is amended as follows:
601.1 Scope. The provisions of this chapter, the 2020 National Electrical Code, and the 2021 International Mechanical Code (all as amended) shall govern the minimum mechanical and electrical facilities and equipment to be provided.
(17) Section 602.3 shall be deleted and replaced as follows:
602.3 Heat Supply. Every owner and operator of any building who rents, leases or lets one or more dwelling units, rooming units, dormitories or guest rooms on terms, either express or implied, to furnish heat to the occupants thereof shall supply sufficient heat during the period from October 1 to May 1 to maintain a room temperature of not less than 68°F / 20°C in all habitable rooms, bathrooms, and toilet rooms.
(18) Section 602.4 is amended as follows:
602.4 Occupiable work spaces. Indoor occupiable work spaces shall be supplied with heat during the period from October 1 to May 1 to maintain a temperature of not less than 65°F / 18°C during the period the spaces are occupied. Exceptions:
1. Processing, storage and operation areas that require cooling or special temperature conditions.
2. Areas in which persons are primarily engaged in vigorous physical activities.
(19) Section 602.6 is added as follows:
602.6 Primary heat source. A fireplace or wood burning appliance shall not be allowed as the required primary heat source for a structure.
(20) Section 603.3 is amended as follows:
603.3 Clearances. All required clearances to combustible structural or finish materials shall be maintained. Clearances of 36 inches (914 mm) shall be maintained for all other combustibles such as stored materials.
(21) Section 603.7 is added as follows:
603.7 Flue. All fuel-burning equipment and appliances shall be connected to an approved chimney or vent. When a water heater is connected to a chimney or vent with a furnace, the water heater shall not be connected below the furnace vent connection. Exception: Fuel-burning equipment and appliances, which are labeled for unvented operation.
(22) Section 604.1 is amended as follows:
604.1 Facilities required. Every occupied building shall be provided with an electrical system in compliance with the requirements of this section, Section 605 and local amendments.
(23) Section 604.2.1 shall be added as follows:
604.2.1 Minimum service requirements--one- and two-family dwelling. If Edison base fuses are in use in the existing panel(s), and there is evidence of over-fusing, the fuses must be replaced with fuse adapters of the "S" type, and "S" type fuses must be installed. When installing a new service in an existing single-family dwelling, or replacing or repairing any part of the existing service equipment, a minimum 3-wire 100 ampere 120/240 volt service shall be required to be installed, with a minimum panel size of 16 spaces. The entire service shall be brought up to all the current code standards adopted by Village of Machesney Park. Exception: Replacement or addition of a branch-circuit overcurrent protective device.
(24) Section 604.2.2 shall be added as follows:
604.2.2 Minimum service requirements--multi-family dwelling. For existing multi-family services no more than two 60 ampere main disconnects shall be allowed on a 100 ampere service, and no more than four 60 ampere main disconnects and one 30 ampere house main disconnect shall be allowed on a 200 ampere service. A panel designated for a specific unit shall serve no other units. If Edison base fuses are in use in the existing panel(s), and there is evidence of over-fusing, the fuses must be replaced with fuse adapters of the "S" type, and "S" type fuses must be installed. When replacing or installing any part of the electrical service in an existing multi-family dwelling, the entire service shall be brought up to all the current code standards adopted by Village. The minimum panel size allowed shall be 12 spaces if that number of spaces is adequate to serve the amount of required circuits in the apartment. Exception: Replacement or addition of a branch-circuit overcurrent protective device.
(25) Section 604.2.3 shall be added as follows:
604.2.3 Main Disconnecting Means. Main disconnecting means and overcurrent protective devices shall be accessible to each tenant of a multi-family building. Overcurrent devices such as fuses or breakers shall be used to protect branch circuit conductors.
(26) Section 604.2.4 shall be added as follows:
604.2.4 Service grounding. The grounded conductor at the main disconnecting means shall be bonded to the main service metal water pipe within 5 feet (1524 mm) of the point of entry of the main water service pipe. A jumper shall be installed around the water meter.
(27) Section 605.1.1 shall be added as follows:
605.1.1 Electrical equipment, wiring, and appliances. No structure shall be deemed to comply with the requirements of this article relating to electrical equipment, wiring, and appliances unless: (a)
Exposed wire. Any exposed knob-and-tube wire has insulation that is in good condition and is properly protected as required by NEC Article 394.
(b) Short circuit. No short circuit or break exists in any electrical conductor.
(c) Shock hazard. No obvious shock hazard exists.
(d) Overload. No circuit shall be overloaded as a result of connecting equipment or appliances to outlets supplied with wire of inadequate size.
(e) Overcurrent protection. Branch circuits shall be protected by breakers or fuses of the proper rating for the wire size.
(f) Devices. Every fixture, receptacle, switch and junction box shall be securely and properly fastened in position.
(g) Maintenance and in good condition. Every fixture, receptacle, and switch shall be properly maintained in workable and safe condition (including proper covers or enclosures), securely fastened to box, and shall be connected to source of electrical power in a safe manner.
(h) Exposed noncurrent-carrying metal parts grounded. All exposed noncurrent-carrying metal parts of the electrical system that are within eight feet (2438 mm) vertically or five feet (1524 mm) horizontally of ground, or a grounded metal object subject to contact by persons, shall be grounded.
(28) Section 605.2.1 shall be added as follows:
605.2.1 Receptacle outlets in dwellings. Receptacle outlets are required in the following locations: (a)
Laundry areas shall have a grounded receptacle within six feet (1829 mm) of the laundry tub. Receptacles mounted on the ceiling do not fulfill this requirement.
(b) Bathroom receptacles shall be installed adjacent to the sink. A receptacle outlet shall not be installed within tub or shower perimeter. All bathroom receptacles shall have ground fault circuit interrupter protection.
(c) Kitchens: a minimum of three duplex wall receptacles are required with two accessible for appliance use. All existing receptacles serving an appliance with a factory installed grounded plug, or serving countertop spaces, shall be properly grounded.
(d) All receptacle outlets which are added or replaced in bathrooms, kitchens, basements, garages, open porches, breezeways, or other locations used by a person standing on the ground or on grounding conductive materials shall be on a grounded system and shall have ground fault circuit interrupter protection.
(e) No receptacle shall be installed in the floor, unless it has an approved box and cover for in-floor use.
(29) Section 605.3 shall be amended as follows:
605.3 Luminaires. Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room, furnace room, utility room, and within 6' of any electrical service panel shall contain not less than one electric luminaire. Pool and spa luminaires over 15V shall have ground fault circuit interrupter protection.
(30) Section 605.3.1 shall be added as follows:
605.3.1 Hall and stairway lighting in multiple dwellings. Every hall and stairway in every multiple dwelling containing five (5) or more units shall be adequately lighted at all times. All multiple dwellings containing four (4) or less units may have conveniently located light switches controlling an adequate lighting system instead of full-time lighting. All exterior stairs shall be adequately lighted and shall be controlled by conveniently located light switches that have been permanently installed.
(31) Section 605.3.2 shall be added as follows:
605.3.2 Wall switches, stairways and exterior exits. Permanently mounted wall switches, not dependent on a battery to operate, to control a luminaire shall be provided in the following locations: (a)
On the interior side of all exterior doorway entrances, unless an automatic means of switching is provided on the outside.
(b) All stairways. If the stairway consists of six or more risers, a three-way switch must be installed at the top and bottom of the stairway.
(32) Section 605.3.3 shall be added as follows:
605.3.3 Wall switches, other rooms. Permanently mounted wall switches, not dependent on a battery to operate, at the point of entry to the room to control a lighting outlet within the room shall be provided in the following locations: (a)
In all bathrooms to control a luminaire. Switches shall be installed so as not to be within tub or shower perimeter.
(b) In kitchens to control a luminaire.
(c) In all habitable rooms to control a luminaire or receptacle.
Source: Legislative text reproduced verbatim
Plain English

Section 8-329 of the Machesney Park Village Code adopts the 2021 ICC International Property Maintenance Code with a series of local amendments tailored to the Village's specific conditions. These amendments cover a wide range of property conditions, including exterior sanitation and debris removal, weed height limits, motor vehicle storage, heat supply requirements, electrical service standards, and lighting requirements. The amendments modify, delete, or add to the base code's sections to establish locally enforceable minimum standards for the maintenance of residential and other occupied structures within Machesney Park.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 10, 2026

Plain English — not legal advice.

For Property Managers

Under § 8-329, property owners and operators in Machesney Park are generally expected to maintain their properties in compliance with both the base 2021 IPMC and the Village's local amendments. Compliant operators typically ensure exterior areas are free of debris and weeds exceeding 7 inches, that rental units are heated to at least 68°F from October 1 to May 1, that electrical systems meet the minimum service and grounding requirements added by the Village, and that all structures display properly sized address numbers. Operators of multi-family buildings also generally ensure that each tenant has accessible main disconnecting means and that common halls and stairways are adequately lit at all times in buildings with five or more units.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Under § 8-329, tenants in Machesney Park have rights tied to the Village's locally amended property maintenance standards, including the right to adequate heat (at least 68°F from October 1 to May 1) and properly maintained electrical systems with accessible overcurrent protection in multi-family buildings. If a rental unit appears to fall short of these standards — such as insufficient heat, unsafe wiring, or inadequate lighting in common areas — tenants may consider documenting the conditions and contacting the Village's code official, who is empowered under this section to order corrective action. Tenants may also wish to consult a local tenant-rights organization to understand how these code requirements may be raised as part of a broader habitability concern.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 10, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

Rules and statutes cited by this regulation

IL Muni § 8-328
Not yet ingested
65 ILCS 5
Not yet ingested
625 ILCS 5
Not yet ingested
IL Muni § 308.3.1
Not yet ingested
IL Muni § 604.2.1
Not yet ingested
IL Muni § 604.2.2
Not yet ingested
IL Muni § 604.2.3
Not yet ingested
IL Muni § 604.2.4
Not yet ingested
IL Muni § 605.1.1
Not yet ingested
IL Muni § 605.2.1
Not yet ingested
IL Muni § 605.3.1
Not yet ingested
IL Muni § 605.3.2
Not yet ingested
IL Muni § 605.3.3
Not yet ingested

References In

No inbound references recorded yet for this provision.

Related Rules

§ 244.260
Compliance required
§ 14.567
ADOPTED BY REFERENCE
§ 244.340
Sewer and water connections

Source Information