Killingly, Conn., Code of Ordinances ch. 4, art. III § 4-48

Smoke Detectors and Carbon Monoxide Detectors

In Force
Verified 11/11/2026 · Next check 2/9/2027
KillinglyHabitability & Repair

Operative Text

Killingly, Conn., Code of Ordinances ch. 4, art. III § 4-48
Section 4-48        Smoke Detectors and Carbon Monoxide Detectors
A. Every dwelling or portion thereof rented to another and every dwelling unit contained in a building that
   contains two or more dwelling units shall be provided within each said dwelling unit with smoke/co detectors
   permanently connected to a standard one-hundred-twenty-volt AC supply or operated by a self-contained
   battery with a minimum of one year of life. The device shall be installed on the ceiling or wall outside of each
   separate sleeping area in the immediate vicinity of bedrooms, in each room used for sleeping purposes and in
   each story within a dwelling unit, including basements and cellars.
B. A smoke/co detector shall be considered to be in noncompliance with this section, even if it is installed in
   accordance with the provisions of this section, if it is connected or allowed to be connected to a switch-off
   electrical circuit other than as required for overcurrent protection or if it is inoperable because of battery
   deterioration or for any other reason or if it is incapable of providing the warning it is designed to provide to
   the occupants of the dwelling and/or dwelling units it is intended to serve for any other reason.
C. For the purposes of this code and the designation described in §§ 4-80A and 4-81 of this code, violations of
   this section are hereby declared to be an immediate hazard to the health, safety and welfare of the occupants
   and the general public.
Source: Legislative text reproduced verbatim
Plain English

Section 4-48 of the Killingly Rental Housing Standards Code requires that every rented dwelling and every unit in a multi-unit building be equipped with smoke and carbon monoxide detectors powered either by a hardwired 120-volt AC connection or a battery with at least one year of life. Detectors must be placed on ceilings or walls outside sleeping areas, inside each room used for sleeping, and on every story of the unit including basements and cellars. A detector is considered non-compliant not only if it is missing or improperly placed, but also if it is connected to a switchable circuit, has a dead or deteriorated battery, or is otherwise inoperable or incapable of providing its intended warning. Violations of this section are formally classified as an immediate hazard to health, safety, and welfare under §§ 4-80A and 4-81 of the same code.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 11, 2026

Plain English — not legal advice.

For Property Managers

Under Section 4-48 of the Killingly Rental Housing Standards Code, compliant property operators ensure that every rented unit has functioning smoke and CO detectors installed at each required location — outside sleeping areas, inside sleeping rooms, and on every floor including basements — before a tenant takes occupancy. Operators generally verify that detectors are hardwired to a non-switchable 120-volt circuit or contain a battery with at least one year of rated life, and they conduct routine checks to confirm devices remain operable and capable of providing their intended warning. Because violations of Section 4-48 are designated an immediate hazard under §§ 4-80A and 4-81, non-compliance carries heightened enforcement consequences compared to ordinary code deficiencies.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Section 4-48 of the Killingly Rental Housing Standards Code gives tenants the right to live in a rental unit equipped with properly installed, fully operational smoke and carbon monoxide detectors at every required location. Because violations of this section are classified as an immediate hazard under §§ 4-80A and 4-81, tenants who find detectors missing, disabled, connected to a switchable circuit, or otherwise inoperable may have grounds to report the condition to the local code enforcement authority responsible for the Killingly Rental Housing Standards Code. Tenants may also wish to document the condition in writing and consult a local tenant-rights organization to understand the full range of options available to them.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 11, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

No inbound references recorded yet for this provision.

Related Rules

§ 244.260
Compliance required
§ 14.567
ADOPTED BY REFERENCE
§ 244.340
Sewer and water connections